GIGABYTE E162-220. Technical specifications

ENG | RUS

High-performance, high-density, single-socket server supporting 3rd Generation Intel Xeon Scalable processors with maximum TDP270W, height 1U.
Server depth is 50 cm, frontal interface arrangement.
Typical application:
High Performance Computing (HPC)
- AI, machine learning
- applications for working with graphics
- network services server
- telecommunications

Previous photo Zoom photo Next photo
Please check availability

Platform characteristics E162-220

Characteristic  Description
PlatformGIGABYTE E162-220 Server Platform
Server BoardGIGABYTE Server Board ME62-GE0
One 3rd Generation Intel? Xeon? Scalable processor, maximum TDP 270W
16 slots for installing DDR4-3200 memory modules
6 SATA ports, 2 PCIe 4.0 x4 ports for NVMe drives, 2 USB 3.0 ports, 3 M.2 PCIe 4.0 x4 slots for drives, IPMI, Dual BIOS, Dual BMC Firmware
3 PCIe 4.0 slots for installing riser cards, 64 PCIe 4.0 lanes
slot for installing a network mezzanine module OCP 3.0 PCIe 4.0 x16
Baseboard Management Controller Aspeed AST2600
Form Factor1U, rack mountable
Processor1 processor from the 3rd Generation Intel? Xeon? Scalable Processors family
Maximum Thermal Design Power (TDP) -270W on the processor
Supported processors: Intel Xeon Silver 4300, Gold 5300, Gold 6300, Platinum 8300, except processors with indexes (H), (L), (U), (Q)
Processor socket Socket-P4 LGA4189, Intel Ice Lake architecture,10nm process technology
From 8 to 40 cores and 80 threads per processor, operating frequency from 2.0 GHz to 3.6 GHz
Up to 80 logical CPUs per server with Intel Hyper-Threading Technology
Up to 60 MB L3 cache per processor (1.5 MB per core), 1.25 MB L2 cache per core, 32 KB + 48 KB L1 cache per core
Maximum amount of RAM supported by the processor6TB
DDR4-2667/2933/3200 MT/s memory support (depending on processor model), 4 dual-channel memory controllers (IMC)
Support for Registered and Load reduced ECC memory, including 3DS
Support for Intel? Optane? Persistent Memory 200 Series (Xeon Gold and Platinum only) in Memory Mode and APP Direct Mode
64 PCIe 4.0 lanes (4GB/s per lane), DMI 3.0 (4 lines)
ChipsetIntel C621A Chipset
System MemoryMemory types:
- DDR4 ECC Registered Memory (RDIMM) 1.2V, DDR4 ECC Registered Memory 3DS (RDIMM 3DS) 1.2V
- DDR4 ECC Load Reduced Memory (LRDIMM) 1.2V, DDR4 ECC Load Reduced Memory 3DS (LRDIMM 3DS) 1.2V
- Intel? Optane? Persistent Memory 200 Series (PMEM), 128GB, 256GB, 512GB modules
Maximum RAM (the processor supports a maximum of 6TB of RAM):
- for RDIMM - 1024 GB (16 x 64 GB), for LRDIMM - 2048 GB (16 x 128 GB)
- for RDIMM 3DS - 2048 GB (16 x 128 GB), for LRDIMM 3DS - 4096 GB (16 x 256 GB)
- for PMEM - 4096 GB in Memory Mode (8 x 512 GB PMEM), 6 TB in APP Direct Mode (8 x 256 GB DDR4 + 8 x 512 GB PMEM)
Memory operating modes: 2666/2933/3200 MT/s (depending on processor model)
4 dual-channel memory controllers (IMC) integrated into the processor
Total 8 channels per CPU, one or two memory modules per channel (1 DPC/2 DPC)
Total 16 memory modules per CPU, 16 memory modules per server
Memory subsystem bandwidth 171/188/205 GB/s (2667/2933/3200 MT/s) per CPU depending on CPU model
Network AdaptersWithout built-in network adapter. Requires installation of network module in OCP slot and/or network card in expansion slot.
Dedicated 1 Gb Ethernet RJ-45 management port
Additionally:
- replaceable network module with installation in the slot on the OCP3.0 PCIe 4.0 x16 motherboard;
- up to two network adapters in standard PCIe 4.0 x16 expansion slots
Expansion SlotsSlots for installing expansion cards:
- 1 PCIe 4.0 x16/x16 full height, full length, double width slot for GPU (Full Height, Full Length, Double Width), connected to CPU via PCIe expander
- 1 PCIe 4.0 x16/x16 Low Profile, Half Length slot, connected to CPU via PCIe expander
- 1 PCIe 4.0 x16/x16 Low Profile, Half Length, Direct CPU Connect
PCIe 4.0 x16 OCP 3.0 slot on the motherboard for installing a network module, direct connection to the CPU
Disk Subsystem ControllerIntegrated chipset SATA controller, 4 6Gb/s ports (1 4-port SFF-8654 SLIMLINE x4 connector):
- support VROC 7.5 RAID 0/1/10/5
Integrated chipset sSATA controller, 2 x 6Gb/s ports (2 x 7-Pin SATA connectors, 1 x SATA DOM port):
- VROC 7.5 RAID 0/1 support
2 PCIe 4.0 x4 ports for connecting NVMe drives (2 SFF-8654 SLIMLINE x4 connectors from CPU):
- support for Intel VMD 2.0, Intel VROC 7.5 RAID 0/1 (RAID requires Intel VROC Key)
PCIe 4.0 x4 ports for M.2 2242/2260/2280/22110 drives, CPU connection;
- support for Intel VMD 2.0, Intel VROC 7.5 RAID 0/1 (RAID requires Intel VROC Key)
1 PCIe 3.0 x4 port for M.2 2280/22110 drives, connected to the chipset.
Additionally (selection in the Configurator fields "Disk subsystem controller" and "HBA adapter):
- RAID controller, HBA adapter or Tri-Mode controller for SAS3 and/or SATA drives in a PCIe 4.0 expansion slot;
- Tri-Mode controller for an alternative option for connecting NVMe drives to the PCIe 4.0 expansion slot.
Disk SubsystemUp to 2 hot-swappable 2.5" SAS3/SATA3/NVMe Gen4 (U.2 or U.3) HDD/SSD drives in a cage on the front panel of the server.
Cable tray connectors: 1 x SLIMLINE x4 connector for SAS3/SATA drives, 2 x SLIMLINE x4 connectors for NVMe PCIe 4.0 x4 drives.
Storage device connection options:
For SATA drives:
to the integrated SATA controller of the motherboard with the SLIMLINE x4 -> SLIMLINE x4 cable (enabled by default).
For SATA and/or SAS drives:
- to SAS RAID controller or HBA with HD Mini-SAS -> SLIMLINE x4 cable (additional cable required);
to the Tri-Mode controller using the HD Mini-SAS -> SLIMLINE x4 or SLIMLINE x8 -> 2 x SLIMLINE x4 cable (depending on the controller model, an additional cable is required).
For NVMe drives:
- to two PCIe 4.0 x4 CPU ports on the motherboard with SLIMLINE x4 -> SLIMLINE x4 cables (enabled by default for two drives);
to the Tri-Mode controller using cables 2 x HD Mini-SAS -> 2 x SLIMLINE x4 or SLIMLINE x8 -> 2 x SLIMLINE x4 (depending on the controller model, an additional cable is required).
Additional StorageOne internal SATA DOM drive installed in the 7-Pin SATA connector of the integrated sSATA controller on the motherboard.
Up to two M.2 PCIe 4.0 x4 drives of format 2242/2260/2280/22110 with installation in connectors on the motherboard, connection to the CPU:
- support for Intel VMD 2.0, Intel VROC 7.5 RAID 0/1 (RAID requires Intel VROC Key)
One M.2 PCIe 3.0 x4 2280/22110 drive installed in a slot on the motherboard, connected to the chipset
Up to two or four M.2 PCIe 3.0 x4 2280/22110 drives installed on an expansion card in a PCIe slot.
- support for Intel VMD 2.0, Intel VROC 7.5 RAID 0/1/10/5 (RAID requires Intel VROC Key)
Up to two M.2 SATA / PCIe 3.0 x4 2280/22110 drives installed on a SAS3408-based expansion card with RAID 0/1 support in a PCIe slot.
Optical StorageNot supported, only external via USB 3.0 port.
InterfacesFront panel: 2 USB 3.0 ports, 1GbE RJ-45 management port, miniDP video port
On the back panel: no
Video Adapter and GPUIntegrated video controller Aspeed? AST2600 Video Graphic Adapter, 1920x1200@60Hz 32bpp, DDR4 SDRAM
It is possible to install a full-size, double-width graphics accelerator with a power consumption of up to 300W.
Control PanelControl buttons: Power, System ID
Indication: Power LED, ID LED, System Status LED
Management and MonitoringIntegrated Baseboard Management Controller Aspeed? AST2600, IPMI 2.0 & Redfish
Built-in RJ-45 1GbE remote management port
Fully functional remote control (KVM, Virtual Media over LAN)
GIGABYTE Management Console
GIGABYTE Server Management (GSM)
Supported Operating SystemsWindows Server 2016
Windows Server 2019
Windows Server 2022
Red Hat Enterprise Linux 7.9 (x64) or later
Red Hat Enterprise Linux 8.2 (x64) or later
Red Hat Enterprise Linux 9.0 (x64) or later
SUSE Linux Enterprise Server 12 SP5 (x64) or later
SUSE Linux Enterprise Server 15 SP2 (x64) or later
Ubuntu 20.04 LTS (x64) or later
Ubuntu 22.04 LTS (x64) or later
VMware ESXi 6.7 Update3 P03 or later
VMware ESXi 7.0 Update2 or later
VMware ESXi 8.0 or later
Citrix Hypervisor 8.2.0 or later
Power Unit2 x 800W 80 Plus Platinum redundant hot-swappable power supplies
Power subsystem operating modes: 1+1 Redundant Power, 2+0 Combined Power
Supported technologies:
Cold Redundancy - at a power consumption level of up to 40% of the maximum, only one power supply is used, which increases energy efficiency by approximately 10%.
Smart Crises Management and Protection (SCMP) GIGABYTE patented technology for high-load systems. When the power consumption level is more than 50% of the maximum, in the event of a power supply failure, the system switches to a low-power mode to prevent unplanned shutdown.
Smart Ride Through (SmaRT) - a technology that prevents the system from shutting down during a short-term (up to 10-20 ms) power failure by reducing energy consumption (throttling).
System Cooling6 controlled dual-rotor fans 40x40x56 mm with redundancy and hot-swappable capability, 29'000 RPM
1 fan in each power supply
Passive Cooled CPU Heatsinks
DimensionsHeight 4.35 cm, width 43.8 cm, depth 50.0 cm
Rack Mount InstallationSliding rails for rack mounting are available as an option
Power Supply Parameters100-240 VAC, 10-5 A, 50-60 Hz
Operating EnvironmentOperating temperature from +10?C to +35?C
Relative humidity from 8% to 80%
Storage temperature from -40?C to +60?C
Relative humidity during storage from 20% to 95%
WarrantyStandard warranty 36 months, 9 x 5, service at the service center