| Characteristic |
Description |
 |  | | Platform | GIGABYTE E162-220 Server Platform |
| Server Board | GIGABYTE Server Board ME62-GE0 One 3rd Generation Intel? Xeon? Scalable processor, maximum TDP 270W 16 slots for installing DDR4-3200 memory modules 6 SATA ports, 2 PCIe 4.0 x4 ports for NVMe drives, 2 USB 3.0 ports, 3 M.2 PCIe 4.0 x4 slots for drives, IPMI, Dual BIOS, Dual BMC Firmware 3 PCIe 4.0 slots for installing riser cards, 64 PCIe 4.0 lanes slot for installing a network mezzanine module OCP 3.0 PCIe 4.0 x16 Baseboard Management Controller Aspeed AST2600 |
| Form Factor | 1U, rack mountable |
| Processor | 1 processor from the 3rd Generation Intel? Xeon? Scalable Processors family Maximum Thermal Design Power (TDP) -270W on the processor Supported processors: Intel Xeon Silver 4300, Gold 5300, Gold 6300, Platinum 8300, except processors with indexes (H), (L), (U), (Q) Processor socket Socket-P4 LGA4189, Intel Ice Lake architecture,10nm process technology From 8 to 40 cores and 80 threads per processor, operating frequency from 2.0 GHz to 3.6 GHz Up to 80 logical CPUs per server with Intel Hyper-Threading Technology Up to 60 MB L3 cache per processor (1.5 MB per core), 1.25 MB L2 cache per core, 32 KB + 48 KB L1 cache per core Maximum amount of RAM supported by the processor6TB DDR4-2667/2933/3200 MT/s memory support (depending on processor model), 4 dual-channel memory controllers (IMC) Support for Registered and Load reduced ECC memory, including 3DS Support for Intel? Optane? Persistent Memory 200 Series (Xeon Gold and Platinum only) in Memory Mode and APP Direct Mode 64 PCIe 4.0 lanes (4GB/s per lane), DMI 3.0 (4 lines) |
| Chipset | Intel C621A Chipset |
| System Memory | Memory types: - DDR4 ECC Registered Memory (RDIMM) 1.2V, DDR4 ECC Registered Memory 3DS (RDIMM 3DS) 1.2V - DDR4 ECC Load Reduced Memory (LRDIMM) 1.2V, DDR4 ECC Load Reduced Memory 3DS (LRDIMM 3DS) 1.2V - Intel? Optane? Persistent Memory 200 Series (PMEM), 128GB, 256GB, 512GB modules Maximum RAM (the processor supports a maximum of 6TB of RAM): - for RDIMM - 1024 GB (16 x 64 GB), for LRDIMM - 2048 GB (16 x 128 GB) - for RDIMM 3DS - 2048 GB (16 x 128 GB), for LRDIMM 3DS - 4096 GB (16 x 256 GB) - for PMEM - 4096 GB in Memory Mode (8 x 512 GB PMEM), 6 TB in APP Direct Mode (8 x 256 GB DDR4 + 8 x 512 GB PMEM) Memory operating modes: 2666/2933/3200 MT/s (depending on processor model) 4 dual-channel memory controllers (IMC) integrated into the processor Total 8 channels per CPU, one or two memory modules per channel (1 DPC/2 DPC) Total 16 memory modules per CPU, 16 memory modules per server Memory subsystem bandwidth 171/188/205 GB/s (2667/2933/3200 MT/s) per CPU depending on CPU model |
| Network Adapters | Without built-in network adapter. Requires installation of network module in OCP slot and/or network card in expansion slot. Dedicated 1 Gb Ethernet RJ-45 management port Additionally: - replaceable network module with installation in the slot on the OCP3.0 PCIe 4.0 x16 motherboard; - up to two network adapters in standard PCIe 4.0 x16 expansion slots |
| Expansion Slots | Slots for installing expansion cards: - 1 PCIe 4.0 x16/x16 full height, full length, double width slot for GPU (Full Height, Full Length, Double Width), connected to CPU via PCIe expander - 1 PCIe 4.0 x16/x16 Low Profile, Half Length slot, connected to CPU via PCIe expander - 1 PCIe 4.0 x16/x16 Low Profile, Half Length, Direct CPU Connect PCIe 4.0 x16 OCP 3.0 slot on the motherboard for installing a network module, direct connection to the CPU |
| Disk Subsystem Controller | Integrated chipset SATA controller, 4 6Gb/s ports (1 4-port SFF-8654 SLIMLINE x4 connector): - support VROC 7.5 RAID 0/1/10/5 Integrated chipset sSATA controller, 2 x 6Gb/s ports (2 x 7-Pin SATA connectors, 1 x SATA DOM port): - VROC 7.5 RAID 0/1 support 2 PCIe 4.0 x4 ports for connecting NVMe drives (2 SFF-8654 SLIMLINE x4 connectors from CPU): - support for Intel VMD 2.0, Intel VROC 7.5 RAID 0/1 (RAID requires Intel VROC Key) PCIe 4.0 x4 ports for M.2 2242/2260/2280/22110 drives, CPU connection; - support for Intel VMD 2.0, Intel VROC 7.5 RAID 0/1 (RAID requires Intel VROC Key) 1 PCIe 3.0 x4 port for M.2 2280/22110 drives, connected to the chipset. Additionally (selection in the Configurator fields "Disk subsystem controller" and "HBA adapter): - RAID controller, HBA adapter or Tri-Mode controller for SAS3 and/or SATA drives in a PCIe 4.0 expansion slot; - Tri-Mode controller for an alternative option for connecting NVMe drives to the PCIe 4.0 expansion slot. |
| Disk Subsystem | Up to 2 hot-swappable 2.5" SAS3/SATA3/NVMe Gen4 (U.2 or U.3) HDD/SSD drives in a cage on the front panel of the server. Cable tray connectors: 1 x SLIMLINE x4 connector for SAS3/SATA drives, 2 x SLIMLINE x4 connectors for NVMe PCIe 4.0 x4 drives. Storage device connection options: For SATA drives: to the integrated SATA controller of the motherboard with the SLIMLINE x4 -> SLIMLINE x4 cable (enabled by default). For SATA and/or SAS drives: - to SAS RAID controller or HBA with HD Mini-SAS -> SLIMLINE x4 cable (additional cable required); to the Tri-Mode controller using the HD Mini-SAS -> SLIMLINE x4 or SLIMLINE x8 -> 2 x SLIMLINE x4 cable (depending on the controller model, an additional cable is required). For NVMe drives: - to two PCIe 4.0 x4 CPU ports on the motherboard with SLIMLINE x4 -> SLIMLINE x4 cables (enabled by default for two drives); to the Tri-Mode controller using cables 2 x HD Mini-SAS -> 2 x SLIMLINE x4 or SLIMLINE x8 -> 2 x SLIMLINE x4 (depending on the controller model, an additional cable is required). |
| Additional Storage | One internal SATA DOM drive installed in the 7-Pin SATA connector of the integrated sSATA controller on the motherboard. Up to two M.2 PCIe 4.0 x4 drives of format 2242/2260/2280/22110 with installation in connectors on the motherboard, connection to the CPU: - support for Intel VMD 2.0, Intel VROC 7.5 RAID 0/1 (RAID requires Intel VROC Key) One M.2 PCIe 3.0 x4 2280/22110 drive installed in a slot on the motherboard, connected to the chipset Up to two or four M.2 PCIe 3.0 x4 2280/22110 drives installed on an expansion card in a PCIe slot. - support for Intel VMD 2.0, Intel VROC 7.5 RAID 0/1/10/5 (RAID requires Intel VROC Key) Up to two M.2 SATA / PCIe 3.0 x4 2280/22110 drives installed on a SAS3408-based expansion card with RAID 0/1 support in a PCIe slot. |
| Optical Storage | Not supported, only external via USB 3.0 port. |
| Interfaces | Front panel: 2 USB 3.0 ports, 1GbE RJ-45 management port, miniDP video port On the back panel: no |
| Video Adapter and GPU | Integrated video controller Aspeed? AST2600 Video Graphic Adapter, 1920x1200@60Hz 32bpp, DDR4 SDRAM It is possible to install a full-size, double-width graphics accelerator with a power consumption of up to 300W. |
| Control Panel | Control buttons: Power, System ID Indication: Power LED, ID LED, System Status LED |
| Management and Monitoring | Integrated Baseboard Management Controller Aspeed? AST2600, IPMI 2.0 & Redfish Built-in RJ-45 1GbE remote management port Fully functional remote control (KVM, Virtual Media over LAN) GIGABYTE Management Console GIGABYTE Server Management (GSM) |
| Supported Operating Systems | Windows Server 2016 Windows Server 2019 Windows Server 2022 Red Hat Enterprise Linux 7.9 (x64) or later Red Hat Enterprise Linux 8.2 (x64) or later Red Hat Enterprise Linux 9.0 (x64) or later SUSE Linux Enterprise Server 12 SP5 (x64) or later SUSE Linux Enterprise Server 15 SP2 (x64) or later Ubuntu 20.04 LTS (x64) or later Ubuntu 22.04 LTS (x64) or later VMware ESXi 6.7 Update3 P03 or later VMware ESXi 7.0 Update2 or later VMware ESXi 8.0 or later Citrix Hypervisor 8.2.0 or later |
| Power Unit | 2 x 800W 80 Plus Platinum redundant hot-swappable power supplies Power subsystem operating modes: 1+1 Redundant Power, 2+0 Combined Power Supported technologies: Cold Redundancy - at a power consumption level of up to 40% of the maximum, only one power supply is used, which increases energy efficiency by approximately 10%. Smart Crises Management and Protection (SCMP) GIGABYTE patented technology for high-load systems. When the power consumption level is more than 50% of the maximum, in the event of a power supply failure, the system switches to a low-power mode to prevent unplanned shutdown. Smart Ride Through (SmaRT) - a technology that prevents the system from shutting down during a short-term (up to 10-20 ms) power failure by reducing energy consumption (throttling). |
| System Cooling | 6 controlled dual-rotor fans 40x40x56 mm with redundancy and hot-swappable capability, 29'000 RPM 1 fan in each power supply Passive Cooled CPU Heatsinks |
| Dimensions | Height 4.35 cm, width 43.8 cm, depth 50.0 cm |
| Rack Mount Installation | Sliding rails for rack mounting are available as an option |
| Power Supply Parameters | 100-240 VAC, 10-5 A, 50-60 Hz |
| Operating Environment | Operating temperature from +10?C to +35?C Relative humidity from 8% to 80% Storage temperature from -40?C to +60?C Relative humidity during storage from 20% to 95% |
| Warranty | Standard warranty 36 months, 9 x 5, service at the service center |
|