| Characteristic |
Description |
 |  | | Platform | GIGABYTE G492-HA0 Server Platform |
| Server Board | GIGABYTE Server Board MG62-G41 One or two 3rd Generation Intel? Xeon? Scalable processors, maximum TDP 270W Interprocessor interface 11.2 GT/s (3 links) 32 slots for installing DDR4-3200 memory modules 14 SATA ports, 8 PCIe 4.0 x4 ports for NVMe drives (4 SLIMLINE x8 connectors), 4 USB 3.0 ports, COM port, IPMI, Dual BIOS 96 PCIe 4.0 lanes (12 SLIMLINE x8 connectors) for connecting riser cards, a total of 128 PCIe 4.0 lanes when installing two CPUs Baseboard Management Controller Aspeed AST2500 |
| Form Factor | 4U, rack mountable |
| Processor | 1 or 2 3rd Generation Intel? Xeon? Scalable Processors Maximum Thermal Design Power (TDP) -270W per processor (all Xeon Scalable Gen3 dual-socket processors) Supported processors: Intel Xeon Silver 4300, Gold 5300, Gold 6300, Platinum 8300, except processors with indexes (H), (L), (U), (Q) Processor socket Socket-P4 LGA4189, Intel Ice Lake architecture,10nm process technology From 8 to 40 cores and 80 threads per processor, operating frequency from 2.0 GHz to 3.6 GHz Up to 160 logical CPUs per server with Intel Hyper-Threading Technology Up to 60 MB L3 cache per processor (1.5 MB per core), 1.25 MB L2 cache per core, 32 KB + 48 KB L1 cache per core Maximum amount of RAM supported by the processor6TB DDR4-2667/2933/3200 MT/s memory support (depending on processor model), 4 dual-channel memory controllers (IMC) Support for Registered and Load reduced ECC memory, including 3DS Support for Intel? Optane? Persistent Memory 200 Series (Xeon Gold and Platinum only) in Memory Mode and APP Direct Mode Interprocessor interface UPI 10.4 (2 links) or 11.2 GT/s (3 links),64 PCIe 4.0 lanes (4GB/s per lane), DMI 3.0 (4 lines) |
| Chipset | Intel C621A Chipset, 20 PCIe 3.0 lanes, 14 SATA ports, 14 USB 2.0, 10 USB 3.0 |
| System Memory | Memory types: - DDR4 ECC Registered Memory (RDIMM) 1.2V, DDR4 ECC Registered Memory 3DS (RDIMM 3DS) 1.2V - DDR4 ECC Load Reduced Memory (LRDIMM) 1.2V, DDR4 ECC Load Reduced Memory 3DS (LRDIMM 3DS) 1.2V - Intel? Optane? Persistent Memory 200 Series (PMEM), 128GB, 256GB, 512GB modules Maximum RAM (the processor supports a maximum of 6TB of RAM): - for RDIMM - 2048 GB (32 x 64 GB), for LRDIMM - 4096 GB (32 x 128 GB) - for RDIMM 3DS - 4096 GB (32 x 128 GB), for LRDIMM 3DS - 8192 GB (32 x 256 GB) - for PMEM - 8192 GB in Memory Mode, 12 TB in APP Direct Mode (16 x 256 GB DDR4 + 16 x 512 GB PMEM) Memory operating modes: 2666/2933/3200 MT/s (depending on processor model) 4 dual-channel memory controllers (IMC) integrated into the processor Total 8 channels per CPU, two memory modules per channel (2 DPC) Total 16 memory modules per CPU, 32 memory modules per server Memory subsystem bandwidth 171/188/205 GB/s (2667/2933/3200 MT/s) per CPU |
| Network Adapters | Integrated network controller Intel Ethernet Controller I550-AT2, 2 ports 10Gb Ethernet RJ-45 Dedicated 1 Gb Ethernet RJ-45 management port Additionally: - up to 4 network adapters in standard PCIe 4.0 expansion slots and OCP 3.0 bay |
| Expansion Slots | - 5 PCIe 4.0 x16 full-height, full-length, double-width slots, connection toCPU#1 - 5 PCIe 4.0 x16 full-height, full-length, double-width slots, connection toCPU#2 (Only functional when a second processor is installed!) - PCIe 4.0 x16/x16 slot, low profile, half length, connection to CPU#1, front; - PCIe 4.0 x16/x16 slot, low profile, half length, connection to CPU#2, front; - PCIe 4.0 x16/x16 slot, low profile, half length, connection to CPU#1, rear; - OCP 3.0 PCIe 4.0 x16/x16 slot, connection to CPU#2, rear. |
| Disk Subsystem Controller | Integrated chipset SATA controller, 8 6Gb/s ports (2 4-port SFF-8654 SLIMLINE x4 connectors): - support VROC 7.5 RAID 0/1/10/5 Integrated chipset sSATA controller, 6 ports 6Gb/s (1 4-port SFF-8654 SLIMLINE x4 connector, 2 7-Pin SATA connectors with SATA DOM support): - support VROC 7.5 RAID 0/1/10/5 8 PCIe 4.0 x4 ports for connecting NVMe drives (2 SFF-8654 SLIMLINE x8 connectors from CPU#1, 2 SFF-8654 SLIMLINE x8 connectors from CPU#2); Supports Intel VMD 2.0, Intel VROC 7.5 RAID 0/1/10/5 (RAID requires Intel VROC Key) Additionally (selection in the Configurator fields "Disk subsystem controller" and "HBA adapter): - RAID controller, HBA adapter or Tri-Mode controller for SAS3 and/or SATA drives in PCIe 4.0 expansion slots; - Tri-Mode controller for an alternative option for connecting NVMe drives to PCIe 4.0 expansion slots. |
| Disk Subsystem | Up to 12 hot-swappable 3.5"/2.5" SAS3/SATA3/NVMe Gen4 HDD/SSD drives in a cage on the front of the server. Cable tray connectors: 3 SLIMLINE x4 connectors for SATA/SAS3 drives, 12 SLIMLINE x4 connectors for NVMe PCIe 4.0 x4 drives. Storage device connection options: For SATA drives: to the integrated SATA controllers of the motherboard with three cables SLIMLINE x4 -> SLIMLINE x4 (enabled by default for 12 drives). For SATA and/or SAS drives: to SAS RAID controller or HBA with HD Mini-SAS -> SLIMLINE x4 cables (up to 12 drives, additional cables required); - to the Tri-Mode controller with cables 2 x HD Mini-SAS -> 2 x SLIMLINE x4 or SLIMLINE x8 -> 2 x SLIMLINE x4 (depending on the controller model, up to 12 drives, additional cables required). For NVMe drives: to 8 PCIe 4.0 x4 ports of the motherboard (4 ports from CPU#1, 4 ports from CPU#2) with SLIMLINE x8 -> 2 x SLIMLINE x4 cables (up to 8 drives, an additional cable is required for each pair of drives); - to the Tri-Mode controller or HBA with cables 2 x HD Mini-SAS -> 2 x SLIMLINE x4 or SLIMLINE x8 -> 2 x SLIMLINE x4 (depending on the controller model, up to 4 drives, an additional cable is required for each pair of drives). |
| Additional Storage | Up to two internal SATA DOM drives installed in the 7-Pin SATA connectors of the integrated sSATA controller on the motherboard. Support Boot RAID 0/1, Intel VROC 7.5 Up to two or four M.2 PCIe 3.0 x4 2280/22110 drives installed on an expansion card in a PCIe slot. Up to two M.2 SATA / PCIe 4.0 x4 2280/22110 drives installed on a SAS3808-based expansion card with RAID 0/1 support in a PCIe slot. |
| Optical Storage | Not supported, only external via USB 3.0 port. |
| Interfaces | Front panel: DB-15 video connector, RJ-45 1GbE management port, 2 USB 3.0 ports, 2 10GbE RJ-45 network ports |
| Video Adapter and GPU | Integrated video controller Aspeed? AST2600 Video Graphic Adapter, 1920x1200@60Hz 32bpp, DDR4 SDRAM It is possible to install up to 8 full-size, double-width graphics accelerators with a power consumption of up to 300W for each. |
| Control Panel | Control buttons: Power, Reset, System ID, NMI Indication: Power LED, ID LED, System Status LED, Drive activity LED |
| Management and Monitoring | Integrated Baseboard Management Controller Aspeed? AST2600, IPMI 2.0 & Redfish Built-in RJ-45 1GbE remote management port Fully functional remote control (KVM, Virtual Media over LAN) GIGABYTE Management Console GIGABYTE Server Management (GSM) |
| Supported Operating Systems | Windows Server 2016 Windows Server 2019 Windows Server 2022 Red Hat Enterprise Linux 7.9 or later Red Hat Enterprise Linux 8.2 or later Red Hat Enterprise Linux 9.0 or later SUSE Linux Enterprise Server 12 SP5 or later SUSE Linux Enterprise Server 15 SP2 or later Ubuntu 20.04 LTS or later Ubuntu 22.04 LTS or later VMware ESXi 6.7 Update3 P03 or later VMware ESXi 7.0 Update2 or later VMware ESXi 8.0 or later Citrix Hypervisor 8.2.0 or later |
| Power Unit | 3 x 2200W 80 Plus Platinum redundant hot-swappable power supplies Power subsystem operating modes: 1+1+1 / 2+1 Redundant Power, 3+0 Combined Power Supported technologies: Cold Redundancy - at a power consumption level of up to 40% of the maximum, only one power supply is used, which increases energy efficiency by approximately 10%. Smart Crises Management and Protection (SCMP) GIGABYTE patented technology for high-load systems. When the power consumption level is more than 50% of the maximum, in the event of a power supply failure, the system switches to a low-power mode to prevent unplanned shutdown. Smart Ride Through (SmaRT) - a technology that prevents the system from shutting down during a short-term (up to 10-20 ms) power failure by reducing energy consumption (throttling). |
| System Cooling | controlled dual-rotor fans 60x60x76 mm with redundancy and hot-swappable capability, 21'700 RPM 1 fan in each power supply CPU radiators with active cooling 4 controlled single-rotor fans 40x40x28 mm with redundancy and hot-swappable capability, 25'000 RPM |
| Dimensions | Height 17.5 cm, width 44.7 cm, depth 88.0 cm |
| Rack Mount Installation | Slide-out rails for rack mounting |
| Power Supply Parameters | 100-240 VAC, 14-13 A, 50-60 Hz |
| Operating Environment | Operating temperature from +10?C to +35?C Relative humidity from 8% to 80% Storage temperature from -40?C to +60?C Relative humidity during storage from 20% to 95% |
| Warranty | Standard warranty 36 months, 9 x 5, service at the service center |
|