| Characteristic |
Description |
 |  |
| Platform | Server platform GIGABYTE R182-Z93 (rev. A00) |
| Server Board | GIGABYTE Server Board MZ92-FS1 Rev. 3.0 One or two AMD EPYC 7003 (Milan) or 7002 (Rome) processors, maximum TDP 280W Interprocessor interface 256 GB/s (64 PCIe 4.0 Lines) 32 slots for installing DDR4-3200 memory modules 16 SATA ports or 4 PCIe 4.0 x4 ports for NVMe drives, 4 USB 3.0 ports, COM port, IPMI, Dual BIOS 2 PCIe 4.0 x32 slots and 1 PCIe 4.0 x16 slot for installing riser cards, 128 PCIe 4.0 lanes when installing two CPUs 2 slots for installing LAN or RAID mezzanine modules: OCP 3.0 PCIe 4.0 x16, OCP 2.0 Type1 PCIe 3.0 x8 Baseboard Management Controller Aspeed AST2500 |
| Form Factor | 1U, rack mountable |
| Processor | 1 or 2 AMD EPYC 7002/7003 processors with a maximum TDP of 280W each For each processor: Processor socket Socket SP3, AMD Zen 2 (Rome) / Zen 3 (Milan) architecture, 7 nm process technology Up to 64 cores, 128 threads, operating frequency up to 3.7 GHz (maximum 4.1 GHz in Boost mode) Up to 256MB L3 cache per CPU, per core: 512KB L2, 64KB (I)+ 32KB (D) L1 Support for Precision Boost technologies, SMT multi-threading 2 x 128-bit FMAC compute units (4 floating point instructions per cycle) 128 PCIe 4.0 lanes per CPU, 64 of which are used as interprocessor interface Supports ECC DDR4-3200 memory, up to 4TB per CPU (up to 8TB total), integrated eight-channel memory controller |
| Chipset | System on Chip (SoC) (the chipset is built into the processor) |
| System Memory | Memory types: - DDR4 ECC Registered Memory (RDIMM) 1.2V, DDR4 ECC Registered Memory 3DS (RDIMM 3DS) 1.2V - DDR4 ECC Load Reduced Memory (LRDIMM) 1.2V, DDR4 ECC Load Reduced Memory 3DS (LRDIMM 3DS) 1.2V Maximum RAM (the processor supports a maximum of 4TB of RAM): - for RDIMM - 2048 GB (32 x 64 GB), for LRDIMM - 4096 GB (32 x 128 GB) - for RDIMM 3DS - 4096 GB (32 x 128 GB), for LRDIMM 3DS - 8192 GB (32 x 256 GB) Memory modes: 3200 MT/s (1 DPC) | 2933, 3200* MT/s (2 DPC), depending on the number of memory modules per channel (DPC) Integrated eight-channel memory controller (IMC) on the processor Total 8 channels per CPU, two memory modules per channel (2 DPC) Total 16 memory modules per CPU, 32 memory modules per server Memory subsystem bandwidth from 85.3 GB/s to 204.8 GB/s depending on the processor model * with appropriate BIOS settings |
| Network Adapters | Integrated network controller Intel Ethernet Controller I350-AM2, 2 ports 1Gb Ethernet RJ-45 Dedicated 1 Gb Ethernet RJ-45 management port Additionally: - replaceable network module with installation in a slot on the OCP 3.0 PCIe 4.0 x16 motherboard; up to two network adapters in standard PCIe 4.0 expansion slots |
| Expansion Slots | Riser Card #1: - 1 x PCIe 4.0 x16/x16 Full Height, Half Length slot, connects toCPU#1 Riser Card #2: - 1 x PCIe 4.0 x16/x16 Full Height, Half Length slot, connects toCPU#2 (Only works when a second processor is installed!) PCIe 4.0 x16 OCP 3.0 slot on the motherboard for installing a network module, connecting toCPU#1. PCIe 4.0 x8 OCP 2.0 Type1 slot on motherboard,busy 2 NVMe Port HBA CNVO132 , connection toCPU#2. (Only works when a second processor is installed!) |
| Disk Subsystem Controller | Integrated into CPU#1 SATA controller, 8 ports 6Gb/s (2 connectors 4-port SFF-8654 SLIMLINE x4),combined with two NVMe PCIe 4.0 x4 ports. Integrated into CPU#2 SATA controller, 8 ports 6Gb/s (2 connectors 4-port SFF-8654 SLIMLINE x4),combined with two NVMe PCIe 4.0 x4 ports. 2 x PCIE 4.0 x4 ports via Dual Port HBA CNVO132 (installed in OCP 2.0 slot) for front cage NVMe drives (2 x SLIMLINE x4 connectors) 4 x PCIE 4.0 x4 ports on Riser Card #3 for NVMe drives in the front cage (4 x SLIMLINE x4 connectors) Additionally (selection in the Configurator fields "Disk subsystem controller" and "HBA adapter): - RAID controller, HBA adapter or Tri-Mode controller in PCIe 4.0 expansion slots for SAS3 and/or SATA drives; - RAID controller, HBA adapter or Tri-Mode controller in PCIe 4.0 expansion slots for alternative connection of NVMe drives. |
| Disk Subsystem | Up to 10 hot-swappable 2.5" SAS3/SATA3/NVMe drivesGen4 HDD/SSD into the basket on the front panel of the server. Cable tray connectors: 3 SLIMLINE x4 connectors for SATA/SAS3 drives, 10 SLIMLINE x4 connectors for NVMe drivesPCIe 4.0 x4 . Storage device connection options: For NVMe drives (10 drives connected by default): - to two PCIe 4.0 x4 CPU#1 ports (connectors on the motherboard) with SLIMLINE x4 -> SLIMLINE x4 cables (2 storage devices connected); - to two PCIe 4.0 x4 CPU#2 ports (connectors on the motherboard) with SLIMLINE x4 -> SLIMLINE x4 cables (2 storage devices connected); to two PCIe 4.0 x4 CPU#2 ports (via Dual Port HBA CNVO132 in OCP 2.0 slot) with SLIMLINE x4 -> SLIMLINE x4 cables (2 storage devices connected); - to four PCIe 4.0 x4 CPU#2 ports (connectors on Riser #3) with SLIMLINE x4 -> SLIMLINE x4 cables (4 storage devices connected); - to Tri-Mode controllers with cables 2 x HD Mini-SAS -> 2 x SLIMLINE x4 or SLIMLINE x8 -> 2 x SLIMLINE x4 (depending on the controller model, up to 8 drives, alternative connection option, additional cables required). Important: Installing more than two NVMe drives requires a dual-processor configuration! For SATA drives: - to integrated SATA controllers CPU#1 and CPU#2 using SLIMLINE x4 -> SLIMLINE x4 cables (up to 10 drives, you can use existing cables). For SATA and/or SAS drives: - to SAS RAID controller or HBA with HD Mini-SAS -> SLIMLINE x4 cables (up to 10 drives, additional cables required); - to the Tri-Mode controller with cables 2 x HD Mini-SAS -> 2 x SLIMLINE x4 or SLIMLINE x8 -> 2 x SLIMLINE x4 (depending on the controller model, up to 10 drives, additional cables required). |
| Additional Storage | M.2 PCIe 4.0 x4 storage device format 2242/2260/2280/22110 installed in a slot on the motherboard. (When installing an M.2 drive, the processor TDP limit is 225W) Up to two or four M.2 PCIe 3.0 x4 2280/22110 drives installed on an expansion card in a PCIe slot. Up to two M.2 SATA / PCIe 3.0 x4 2280/22110 drives installed on a SAS3408-based expansion card with RAID 0/1 support in a PCIe slot. |
| Optical Storage | Not supported, only external via USB 3.0 port. |
| Interfaces | Front panel: 1 USB 3.0 connector On the rear panel: DB-15 video connector, RJ-45 1GbE management port, 2 USB 3.0 ports, 2 1GbE RJ-45 network ports, ID Button with LED Internal ports: Serial Port |
| Video Adapter and GPU | Integrated video controller Aspeed? AST2500 Video Graphic Adapter, 1920x1200@60Hz 32bpp, DDR4 SDRAM It is possible to install up to two graphic accelerators. |
| Control Panel | Control buttons: Power, Reset, System ID, NMI Indication: Power LED, ID LED, System Status LED, Drive activity LED, LAN 1/2 Activity LED |
| Management and Monitoring | Integrated Baseboard Management Controller Aspeed? AST2500, IPMI 2.0 & Redfish Built-in RJ-45 1GbE remote management port Fully functional remote control (KVM, Virtual Media over LAN) GIGABYTE Management Console GIGABYTE Server Management (GSM) |
| Supported Operating Systems | Windows Server 2016 (X2APIC/256T not supported) Windows Server 2019 Windows Server 2022 Red Hat Enterprise Linux 8.3 (x64) or later Red Hat Enterprise Linux 9 SUSE Linux Enterprise Server 12 SP5 (x64) or later SUSE Linux Enterprise Server 15 SP2 (x64) or later Ubuntu 18.04.5 LTS (x64) or later Ubuntu 20.04 LTS (x64) or later Ubuntu 22.04 LTS (x64) or later VMware ESXi 6.7 Update3 P03 or later VMware ESXi 7.0 Update1 or later Citrix Hypervisor 8.2.0 or later |
| Power Unit | 2 x 1200W 80 Plus Platinum redundant hot-swappable power supplies Power subsystem operating modes: 1+1 Redundant Power, 2+0 Combined Power Supported technologies: Cold Redundancy - at a power consumption level of up to 40% of the maximum, only one power supply is used, which increases energy efficiency by approximately 10%. Smart Crises Management and Protection (SCMP) GIGABYTE patented technology for high-load systems. When the power consumption level is more than 50% of the maximum, in the event of a power supply failure, the system switches to a low-power mode to prevent unplanned shutdown. Smart Ride Through (SmaRT) - a technology that prevents the system from shutting down during a short-term (up to 10-20 ms) power failure by reducing energy consumption (throttling). |
| System Cooling | controlled dual-rotor fans 40x40x56 mm with redundancy and hot-swappable capability, 23'000 RPM 1 fan in each power supply CPU radiators with passive cooling, low profile. |
| Dimensions | Height 4.35 cm, width 43.8 cm, depth 73.0 cm |
| Rack Mount Installation | Slide-out rails for rack mounting |
| Power Supply Parameters | 100-240 VAC, 12 -7 A, 50-60 Hz |
| Operating Environment | Operating temperature from +10?C to +35?C Relative humidity from 8% to 80% Storage temperature from -40?C to +60?C Relative humidity during storage from 20% to 95% |
| Warranty | Standard warranty 36 months, 9 x 5, service at the service center |