www.team.ru
Поиск
sales@team.ru

GIGABYTE R183-Z91-AAD1. Technical specifications

ENG | RUS

High-performance dual-processor server with support for processorsAMD EPYC 9004 with a maximum TDP of 400W, height 1U
Typical application:
- universal high-performance business application server
- virtual machine platform
- AI, machine learning
- applications for working with graphics
- network services server
- server for 1C

Previous photo Zoom photo Next photo
In stock

Platform characteristics R183-Z91-AAD1

Characteristic  Description
PlatformServer platform GIGABYTE R183-Z91-AAD1
Server BoardGIGABYTE Server Board MZ93-FS0
One or two AMD EPYC 9004 processors (Genoa/Bergamo), maximum TDP 400W
Interprocessor interface 512 GB/s (64 PCIe 5.0 Lines)
24 slots for installing DDR5-4800 memory modules
16 SATA ports, 4 USB 3.2 Gen1 ports, IPMI, 3 M.2 PCIe 2280/22110 slots
4 PCIe 5.0 x16 slots for installing riser cards, 2 PCIe 5.0 x16 OCP 3.0 slots, 128 PCIe 5.0 lanes when installing two CPUs
4 PCIe 5.0 x4 ports for connecting NVMe drives from CPU#2 (2 Mini Cool Edge IO x8 connectors)
Baseboard Management Controller Aspeed AST2600
Form Factor1U, rack mountable
Processor1 or 2 AMD EPYC 9004 processors with a maximum TDP of 400W each, support for AMD 3D V-Cache Technology
For each processor:
Processor socket Socket SP5 (LGA 6096), AMD Zen 4 (Genoa/Bergamo) architecture, 5 nm process technology
Up to 128 cores, 256 threads, operating frequency up to 4.1 GHz (maximum 4.4 GHz in Boost mode)
Up to 1152 MB L3 cache per CPU, per core: 1024 KB L2, 32 KB (I)+ 32 KB (D) L1
Support for AMD Infinity Guard, AMD Infinity Architecture technologies
128 PCIe 5.0 lanes per CPU, 64 of which are used as interprocessor interface
Supports ECC DDR5-4800 memory, up to 6 TB per CPU (up to 12 TB total), integrated 12-channel memory controller
ChipsetSystem on Chip (SoC) (the chipset is built into the processor)
System MemoryMemory types:
- DDR5 ECC Registered Memory (RDIMM) 1.1V, DDR5 ECC Registered Memory 3DS (RDIMM 3DS) 1.1V
Maximum RAM (the processor supports a maximum of 6TB of RAM):
- for RDIMM - 1536 GB (24 x 64 GB)
- for RDIMM 3DS - 6144 GB (24 x 256 GB)
Memory modes: 4800 MT/s (1 DPC)
Integrated 12-channel memory controller (IMC) on the processor
Total 12 channels per CPU, one memory module per channel (1 DPC)
Total 12 memory modules per CPU, 24 memory modules per server
Memory subsystem bandwidth 460.8 GB/s
Network AdaptersIntegrated network controller Intel Ethernet Controller I350-AM2, 2 ports 1Gb Ethernet RJ-45
Dedicated 1 Gb Ethernet RJ-45 management port
Additionally:
- up to two network modules with installation in the connectors on the OCP 3.0 motherboardPCIe 5.0 x16;
- up to two network adapters in standard expansion slotsPCIe 5.0 x16
Expansion SlotsRiser Card #1:
- 1 slotPCIe 5.0 x16/x16 Full Height, Half Length, Connect toCPU#1
Riser Card #2:
- 1 slotPCIe 5.0 x16/x16 Full Height, Half Length, Connect toCPU#2
(Only works when a second processor is installed!)
SlotPCIe 5.0 x16 OCP 3.0 on the motherboard for installing a network module, connecting toCPU#1
SlotPCIe 5.0 x16 OCP 3.0 on the motherboard for installing a network module, connecting toCPU#2
(Only works when a second processor is installed!)
Disk Subsystem ControllerIntegrated into CPU#1 SATA controller, 16 ports 6Gb/s (1 SFF-TA-1016 MCIO x8 connector, 2 SFF-TA-1016 MCIO x4 connectors)
PCIe 5.0 x4 ports for NVMe drives (1 SFF-TA-1016 MCIO x16 connector from CPU#1; 2 SFF-TA-1016 MCIO x8 connectors from CPU#2)
Additionally (selection in the Configurator fields "Disk subsystem controller" and "HBA adapter):
- RAID controller, HBA adapter or Tri-Mode controller in the PCIe 5.0 expansion slot for SAS3 and/or SATA drives;
- Tri-Mode controller for an alternative option for connecting NVMe drives to PCIe 5.0 expansion slots.
Disk SubsystemUp to 4 hot-swappable 3.5"/2.5" SAS3/SATA3/NVMe Gen4 U.2/U.3 HDD/SSD drives in the lower cage on the front panel of the server.
Connectors on the basket for connecting cables:
- 4 7-Pin SATA connectors for SAS3/SATA drives;
4 SLIMLINE x4 connectors for NVMe PCIe 4.0 x4 drives (U.2 or U.3)
Storage device connection options:
For SATA drives:
- to the integrated SATA controller CPU#1 with the cable MCIO x4 -> 4 x 7-Pin SATA with Side-Band (enabled by default for four drives).
For SATA and/or SAS drives:
- to a SAS RAID controller or HBA via HD Mini-SAS to 4 x 7-Pin SATA w/SB cable (up to four drives, additional cable required);
- to the Tri-Mode controller via HD Mini-SAS -> 4 x 7-Pin SATA w/SB or SLIMLINE x8 -> 4 x 7-Pin SATA cable (depending on the controller model, up to four drives, additional cable required).
For NVMe drives:
- to four PCIe 5.0 x4 ports from CPU#1 on the motherboard with a MCIO x16 -> 4 x SLIMLINE x4 cable (enabled by default for four drives);
- to the Tri-Mode controller using cables 2 x HD Mini-SAS -> 2 x SLIMLINE x4 or SLIMLINE x8 -> 2 x SLIMLINE x4 (depending on the controller model, up to four drives, an additional cable is required for each pair of drives).
Up to 4 hot-swappable 2.5" SATA3/NVMe Gen4 U.2/U.3 SSD drives (9.5mm or less in height) in the top cage on the front panel of the server.
Connectors on the basket for connecting cables:
2 SLIMLINE x2/x4 connectors for SAS3/SATA drives (2 drives per connector);
4 SLIMLINE x4 connectors for NVMe PCIe 4.0 x4 drives (U.2 or U.3)
Storage device connection options:
For SATA drives:
- to the integrated SATA controller CPU#1 with cable MCIO x4 -> 2 x SLIMLINE x2/x4 (enabled by default for four drives).
- to SAS RAID controller or HBA with HD Mini-SAS -> SLIMLINE x4 cables (to 8 ports via 2 cables, additional cables required);
to the Tri-Mode controller with two cables HD Mini-SAS -> SLIMLINE x4 or SLIMLINE x8 -> 2 x SLIMLINE x4 (depending on the controller model, for 8 ports, additional cables are required).
For NVMe drives:
- to four PCIe 5.0 x4 ports fromCPU#2 on the motherboard with two cables MCIO x8 -> 2 x SLIMLINE x4 (enabled by default for four drives);
to the Tri-Mode controller using cables 2 x HD Mini-SAS -> 2 x SLIMLINE x4 or SLIMLINE x8 -> 2 x SLIMLINE x4 (depending on the controller model, an additional cable is required for each pair of drives).
Additional StorageUp to three M.2 2280/22110 drives installed in a slot on the motherboard:
- PCIe 3.0 x4 from CPU#1
- PCIe 3.0 x4 from CPU#2
- PCIe 3.0 x2 from CPU#2
Up to two or four M.2 PCIe 3.0 x4 2280/22110 drives installed on an expansion card in a PCIe slot.
Up to two M.2 SATA / PCIe 4.0 x4 2280/22110 drives installed on a SAS3808-based expansion card with RAID 0/1 support in a PCIe slot.
Optical StorageNot supported, only external via USB 3.2 port.
Interfaces Front panel: 1 USB 3.2 Gen1
On the rear panel: Mini-DP video connector (D-Sub adapter included), RJ-45 1GbE management port, 2 1GbE RJ-45 network ports, 2 USB 3.2 Gen1 ports
Video Adapter and GPUIntegrated video controller Aspeed? AST2600 Video Graphic Adapter, 1920x1200@60Hz 32bpp, DDR4 SDRAM
It is possible to install an additional video card
Control PanelOn the front panel:
- control buttons: Power, Reset, System ID, NMI
indication: Power LED, ID LED, System Status LED, Drive activity LED, LAN Activity LED
On the back panel:
- indication: ID LED
Management and MonitoringIntegrated Baseboard Management Controller Aspeed? AST2600, IPMI 2.0 & Redfish
Built-in RJ-45 1GbE remote management port
Fully functional remote control (KVM, Virtual Media over LAN)
GIGABYTE Management Console
GIGABYTE Server Management (GSM)
Supported Operating SystemsCurrent list
Power Unitx 1600W 80 Plus Platinum PSUs with redundancy and hot swappability
Power subsystem operating modes: 1+1 Redundant Power, 2+0 Combined Power
Supported technologies:
Cold Redundancy - at a power consumption level of up to 40% of the maximum, only one power supply is used, which increases energy efficiency by approximately 10%.
Smart Crises Management and Protection (SCMP) GIGABYTE patented technology for high-load systems. When the power consumption level is more than 50% of the maximum, in the event of a power supply failure, the system switches to a low-power mode to prevent unplanned shutdown.
Smart Ride Through (SmaRT) - a technology that prevents the system from shutting down during a short-term (up to 10-20 ms) power failure by reducing energy consumption (throttling).
System Cooling8 controlled dual-rotor fans 40x40x56 mm with redundancy and hot-swappable capability, 32'000 RPM
1 fan in each power supply
Passive Cooled CPU Heatsinks
DimensionsHeight 4.35 cm, width 43.8 cm, depth 81.5 cm
Rack Mount InstallationSlide-out rails for rack mounting
Power Supply Parameters100-240 VAC, 12-10 A, 50-60 Hz
Operating EnvironmentOperating temperature from +10?C to +35?C
Relative humidity from 8% to 80%
Storage temperature from -40?C to +60?C
Relative humidity during storage from 20% to 95%
WarrantyStandard warranty 36 months, 9 x 5, service at the service center