GIGABYTE R262-ZA2. Technical specifications

ENG | RUS

High-performance server with support for AMD EPYC 7003/7002 processors with a maximum TDP of 240W and two GPUs, 2U height
Typical application:
- universal high-performance business application server
- virtual machine platform
- AI, machine learning
- applications for working with graphics
- server for 1C

Previous photo Zoom photo Next photo
Please check availability

Platform characteristics R262-ZA2

Characteristic  Description
PlatformGIGABYTE R262-ZA2 Server Platform (rev. A00)
Server BoardGIGABYTE Server Board MZA2-CE0 Rev. 3.0
One AMD EPYC 7003 (Milan) or 7002 (Rome) processor, max TDP 240W
16 slots for installing DDR4-3200 memory modules
8 SATA ports or 2 PCIe 4.0 x4 ports for NVMe drives, 4 USB 3.0 ports, COM port, IPMI
4 PCIe 4.0 slots for installing riser cards, 128 PCIe 4.0 lanes
2 slots for installing mezzanine modules OCP 3.0 PCIe 4.0 x16 and OCP 2.0 PCIe 3.0 x16 Type1 P1, P2, P3, P4; Type2 P5
Baseboard Management Controller Aspeed AST2500
Form Factor2U, rack mountable
Processor1 x AMD EPYC 7002/7003 processor with max TDP 240W
Processor socket Socket SP3, AMD Zen 2 (Rome) / Zen 3 (Milan) architecture, 7 nm process technology
Up to 64 cores, 128 threads, operating frequency up to 3.7 GHz (maximum 4.1 GHz in Boost mode)
Up to 256MB L3 cache per CPU, per core: 512KB L2, 64KB (I)+ 32KB (D) L1
Support for Precision Boost technologies, SMT multi-threading
2 x 128-bit FMAC compute units (4 floating point instructions per cycle)
128 PCIe 4.0 lanes per CPU
Supports ECC DDR4-3200 memory, up to 4TB, integrated eight-channel memory controller
ChipsetSystem on Chip (SoC) (the chipset is built into the processor)
System MemoryMemory types:
- DDR4 ECC Registered Memory (RDIMM) 1.2V, DDR4 ECC Registered Memory 3DS (RDIMM 3DS) 1.2V
- DDR4 ECC Load Reduced Memory (LRDIMM) 1.2V, DDR4 ECC Load Reduced Memory 3DS (LRDIMM 3DS) 1.2V
Maximum RAM (the processor supports a maximum of 4TB of RAM):
- for RDIMM - 1024 GB (16 x 64 GB), for LRDIMM - 2048 GB (16 x 128 GB)
- for RDIMM 3DS - 2048 GB (16 x 128 GB), for LRDIMM 3DS - 4096 GB (16 x 256 GB)
Memory modes: 3200 MT/s (1 DPC) | 2933, 3200* MT/s (2 DPC), depending on the number of memory modules per channel (DPC)
Integrated eight-channel memory controller (IMC) on the processor
Total 8 channels per CPU, two memory modules per channel (2 DPC)
Total 16 memory modules per server
Memory subsystem bandwidth 204.8 GB/s
* with appropriate BIOS settings
Network AdaptersIntegrated network controller Intel Ethernet Controller I350-AM2, 2 ports 1Gb Ethernet RJ-45
Dedicated 1 Gb Ethernet RJ-45 management port
Additionally:
- replaceable network module with installation in the slot on the OCP3.0 PCIe 4.0 x16 motherboard;
- replaceable network module with installation in a slot on the OCP2.0 PCIe 3.0 x8 motherboard;
- up to eight network adapters in standard PCIe 4.0/3.0 expansion slots.
Expansion SlotsRiser Card #1:
1 x16/x16 or x8/x16 PCIe 4.0 Full Height, Full Length slot, shares 8 PCIe lanes with slot 2;
- 1 x0/x8 or x8/x8 PCIe 4.0 Full Height, Full Length slot, shares 8 PCIe lanes with slot 1;
- 1 PCIe 4.0 x16/x16 Full Height, Half Length slot.
Riser Card #2:
1 x16/x16 or x8/x16 PCIe 4.0 Full Height, Full Length slot, shares 8 PCIe lanes with slot 2;
- 1 x0/x8 or x8/x8 PCIe 4.0 Full Height, Full Length slot, shares 8 PCIe lanes with slot 1;
- 1 x16/x16 PCIe 4.0 Full Height, Half Length slot, shares 8 PCIe lanes with OCP 2.0 slot.
Riser Card #3:
- 1 PCIe 4.0 x8/x8 Low Profile, Half Length slot;
- 1 PCIe 4.0 x8/x8 Low Profile, Half Length slot.
Riser card #4 (for installing internal expansion card):
- 1 PCIe 4.0 x16/x16 Full Height, Half Length slot, internal
(4 x NVMe PCIe 4.0 x4 Port HBA Occupied)
PCIe 4.0 x16 OCP 3.0 slot on the motherboard.
PCIe 3.0 x8 OCP 2.0 Type1 connector on the motherboard, shares 8 PCIe lanes with slot 3 of riser card 2.
Disk Subsystem ControllerIntegrated CPU SATA controller, 8 x 6Gb/s ports, 2 x 4-port SFF-8654 SLIMLINE x4 connectors, combined with 2 x PCIe 4.0 x4 ports for NVMe drives.
4 PCIe 4.0 x4 ports for NVMe drives via CNV3134 (4 NVMe PCIe 4.0 x4 Port HBA, 4 SFF-8654 SLIMLINE x4 connectors.
x M.2 PCIe 4.0 x4 storage slot, 2280/22110 form factor.
Additionally (selection in the Configurator fields "Disk subsystem controller" and "HBA adapter):
- RAID controller, HBA adapter or Tri-Mode controller for SAS3 and/or SATA drives in PCIe expansion slots.
Disk SubsystemUp to 12 hot-swappable 3.5"/2.5" SAS3/SATA3/NVMe Gen4 HDD/SSD drives in a cage on the front of the server.
Cable tray connectors: 3 SLIMLINE x4 connectors for SATA/SAS3 drives, 12 SLIMLINE x4 connectors for NVMe drives.
Storage device connection options:
For SATA drives:
- to the integrated SATA-controller of the CPU with the cable SLIMLINE x4 -> SLIMLINE x4 (4 storage devices connected);
For SATA and/or SAS drives:
to the GIGABYTE SAS RAID module using SLIMLINE x4 -> SLIMLINE x4 cables (for up to 8 more drives, additional cables required);
to a SAS RAID controller or HBA with HD Mini-SAS -> SLIMLINE x4 cables (up to 12 drives in total, for 8 drives cables in a kit);
- to the Tri-Mode controller using cables HD Mini-SAS -> SLIMLINE x4 or SLIMLINE x8 -> 2 x SLIMLINE x4 (depending on the controller model, up to 12 drives in total, additional cables required).
For NVMe drives:
- to four PCIe 4.0 x4 ports (via HBA CNV3134) with four SLIMLINE x4 -> SLIMLINE x4 cables (enabled by default for four drives);
to the Tri-Mode controller with additional cables 2 x HD Mini-SAS -> 2 x SLIMLINE x4 or SLIMLINE x8 -> 2 x SLIMLINE x4 (depending on the controller model, up to 4 drives).
Up to 2 hot-swappable 2.5" SATA3/SAS HDD/SSD drives in a cage on the rear panel of the server.
Cable tray connectors: 1 x SLIMLINE x4 connector for SATA/SAS3 drives.
Storage device connection options:
For SATA drives:
to the integrated SATA-controller of the CPU with the cable SLIMLINE x4 -> SLIMLINE x4 (enabled by default for 2 drives).
For SATA and/or SAS drives:
- to SAS RAID controller or HBA with HD Mini-SAS -> SLIMLINE x4 cable (for 2 drives, additional cable required);
- to the Tri-Mode controller using the HD Mini-SAS -> SLIMLINE x4 or SLIMLINE x8 -> 2 x SLIMLINE x4 cable (depending on the controller model, for 2 drives, an additional cable is required).
Additional StorageM.2 PCIe 4.0 x4 2280/22110 drive installed in a slot on the motherboard.
Up to two or four M.2 PCIe 3.0 x4 2280/22110 drives installed on an expansion card in a PCIe slot.
Up to two M.2 SATA / PCIe 3.0 x4 2280/22110 drives installed on a SAS3408-based expansion card with RAID 0/1 support in a PCIe slot.
Optical StorageNot supported, only external via USB 3.0 port.
Interfaces Front panel: 2 USB 3.0 ports
On the rear panel: DB-15 video connector, RJ-45 1GbE management port, 2 USB 3.0 ports, 2 1GbE RJ-45 network ports, ID Button with LED
Internal ports: COM port
Video Adapter and GPUIntegrated video controller Aspeed? AST2500 Video Graphic Adapter, 1920x1200@60Hz 32bpp, DDR4 SDRAM
Control PanelControl buttons: Power, Reset, System ID, NMI
Indication: Power LED, ID LED, System Status LED, Drive activity LED, LAN 1/2 Activity LED
Management and MonitoringIntegrated Baseboard Management Controller Aspeed? AST2500, IPMI 2.0 & Redfish
Built-in RJ-45 1GbE remote management port
Fully functional remote control (KVM, Virtual Media over LAN)
GIGABYTE Management Console
GIGABYTE Server Management (GSM)
Supported Operating SystemsWindows Server 2016 (X2APIC/256T not supported)
Windows Server 2019
Windows Server 2022
Red Hat Enterprise Linux 8.3 (x64) or later
Red Hat Enterprise Linux 9 (x64) or later
SUSE Linux Enterprise Server 12 SP5 (x64) or later
SUSE Linux Enterprise Server 15 SP2 (x64) or later
Ubuntu 18.04.5 LTS (x64) or later
Ubuntu 20.04 LTS (x64) or later
Ubuntu 22.04 LTS (x64) or later
VMware ESXi 6.7 Update3 P03 or later
VMware ESXi 7.0 Update1 or later
Citrix Hypervisor 8.2.0 or later
Power Unitx 1600W 80 Plus Platinum PSUs with redundancy and hot swappability
Power subsystem operating modes: 1+1 Redundant Power, 2+0 Combined Power
Supported technologies:
Cold Redundancy - at a power consumption level of up to 40% of the maximum, only one power supply is used, which increases energy efficiency by approximately 10%.
Smart Crises Management and Protection (SCMP) GIGABYTE patented technology for high-load systems. When the power consumption level is more than 50% of the maximum, in the event of a power supply failure, the system switches to a low-power mode to prevent unplanned shutdown.
Smart Ride Through (SmaRT) - a technology that prevents the system from shutting down during a short-term (up to 10-20 ms) power failure by reducing energy consumption (throttling).
System Cooling4 controlled single-rotor fans 80x80x38 mm with redundancy and hot-swappable capability, 16'300 RPM
1 fan in each power supply
CPU heatsink with passive cooling, low profile.
DimensionsHeight 8.75 cm, width 43.8 cm, depth 73.0 cm
Rack Mount InstallationSlide-out rails for rack mounting
Power Supply Parameters100-240 VAC, 12 - 7 A, 50-60 Hz
Operating EnvironmentOperating temperature from +10?C to +35?C
Relative humidity from 8% to 80%
Storage temperature from -40?C to +60?C
Relative humidity during storage from 20% to 95%
WarrantyStandard warranty 36 months, 9 x 5, service at the service center