High-performance server with support for AMD EPYC 7003/7002 processors with a maximum TDP of 280W, 2U height
Support for AMD EPYC 7003 Series Processors with AMD 3D V-Cache
Typical application:
- universal high-performance business application server
- virtual machine platform
- database server
- high-performance storage system
- network services server
- server for 1C

Previous photo Zoom photo Next photo
Please check availability

Platform characteristics R272-Z32

Characteristic  Description
PlatformGIGABYTE R272-Z32 Server Platform (rev. A00)
Server BoardGIGABYTE Server Board MZ32-AR0
One AMD EPYC 7003 (Milan) or 7002 (Rome) processor, max TDP 280W
Support for AMD EPYC 7003 Series Processors with AMD 3D V-Cache
16 slots for installing DDR4-3200 memory modules
8 SATA ports and 4 PCIe 4.0 x4 ports for NVMe drives, 5 USB 3.0 ports, 2 COM ports, IPMI
7 PCIe 4.0 / PCIe 3.0 slots, 128 PCIe 4.0 lanes
Slot for installing mezzanine module OCP 2.0 PCIe 3.0 x16 Type1 P1, P2, P3, P4; Type2 P5
Baseboard Management Controller Aspeed AST2500
Form Factor2U, rack mountable
Processor1 x AMD EPYC 7002/7003 processor with max TDP 280W
Support for AMD EPYC 7003 Series Processors with AMD 3D V-Cache
Processor socket Socket SP3, AMD Zen 2 (Rome) / Zen 3 (Milan) architecture, 7 nm process technology
Up to 64 cores, 128 threads, operating frequency up to 3.7 GHz (maximum 4.1 GHz in Boost mode)
Up to 256MB L3 cache per CPU,768MB L3 for AMD EPYC 7003 Series Processors with AMD 3D V-Cache, per core: 512KB L2, 64KB (I)+ 32KB (D) L1
Support for Precision Boost technologies, SMT multi-threading
2 x 128-bit FMAC compute units (4 floating point instructions per cycle)
128 PCIe 4.0 lanes per CPU
Supports ECC DDR4-3200 memory, up to 4TB, integrated eight-channel memory controller
ChipsetSystem on Chip (SoC) (the chipset is built into the processor)
System MemoryMemory types:
- DDR4 ECC Registered Memory (RDIMM) 1.2V, DDR4 ECC Registered Memory 3DS (RDIMM 3DS) 1.2V
- DDR4 ECC Load Reduced Memory (LRDIMM) 1.2V, DDR4 ECC Load Reduced Memory 3DS (LRDIMM 3DS) 1.2V
Maximum RAM (the processor supports a maximum of 4TB of RAM):
- for RDIMM - 1024 GB (16 x 64 GB), for LRDIMM - 2048 GB (16 x 128 GB)
- for RDIMM 3DS - 2048 GB (16 x 128 GB), for LRDIMM 3DS - 4096 GB (16 x 256 GB)
Memory operating modes: 2933 (2 DPC) /3200 (1 DPC) MT/s (depending on the number of memory modules per channel (DPC))
Integrated eight-channel memory controller (IMC) on the processor
Total 8 channels per CPU, two memory modules per channel (2 DPC)
Total 16 memory modules per server
Memory subsystem bandwidth from 85.3 GB/s to 204.8 GB/s depending on the processor model
Network AdaptersIntegrated network controller Intel Ethernet Controller I350-AM2, 2 ports 1Gb Ethernet RJ-45
Dedicated 1 Gb Ethernet RJ-45 management port
Additionally:
- replaceable network module with installation in a slot on the OCP2.0 PCIe 3.0 x8 motherboard;
up to six network adapters in standard PCIe 4.0/3.0 expansion slots
Expansion SlotsSeven low-profile expansion slots:
Slot #1 - PCIe 3.0 x16 or x8/x16 (shares 8 PCIe 3.0 lines with Slot #2, occupied by CNV3024 HBA adapter with 4 NVMe ports;
Slot #2 - PCIe 3.0 x8/x8 or x0/x8 (shares 8 PCIe 3.0 lanes with Slot #1, not used;
Slot #3 - PCIe 4.0 x16, occupied by HBA adapter CNV3024 with 4 NVMe ports;
Slot #4 - PCIe 4.0 x16, occupied by HBA adapter CNV3024 with 4 NVMe ports;
Slot No. 5 - PCIe 4.0 x8/x16,free;
Slot #6 - PCIe 4.0 x16, occupied by HBA adapter CNV3024 with 4 NVMe ports;
Slot #7 - PCIe 4.0 x16, not used.
The PCIe 3.0 x16 OCP 2.0 slot on the motherboard is occupied by the CNVO124 HBA adapter with 4 NVMe ports.
Disk Subsystem ControllerIntegrated CPU SATA controller, 8 6Gb/s ports, 2 4-port SFF-8654 SLIMLINE x4 connectors.
20 PCIe 3.0 x4 ports for NVMe drives, 20 SFF-8654 SLIMLINE x4 connectors, connection to the CPU, via five 4-Port HBA adapters.
4 PCIe 4.0 x4 ports for NVMe drives, 4 SFF-8654 SLIMLINE x4 connectors on the motherboard, connection to the CPU, combined with slot #7.
2 slots for M.2 PCIe 3.0 x4 storage devices, form factor 2242/2260/2280.
Additionally (selection in the Configurator fields "Disk subsystem controller" and "HBA adapter):
RAID controller, HBA adapter or Tri-Mode controller for SAS3 and/or SATA drives in a PCIe expansion slot.
Disk SubsystemUp to 24 hot-swappable 2.5" NVMe/SAS/SATA SSD drives in a cage on the front of the server.
Connectors on the basket: 6 SLIMLINE x4 connectors for SAS/SATA drives, 3 connectors for expansion cards.
3 expansion cards for the NVMe drive cable cage are installed.
Cable cage expansion card connectors: 24 SLIMLINE x4 connectors for NVMe drives.
Connecting NVMe drives to motherboard ports and HBA adapters,enabled by default for 24 drives.
For SATA drives:
- to the integrated SATA controller of the CPU using the SLIMLINE x4 -> SLIMLINE x4 cable (up to 4 drives, additional cable required).
For SATA and/or SAS drives:
- to SAS RAID controller or HBA with HD Mini-SAS -> SLIMLINE x4 cables (up to 16 drives, additional cables required);
to the Tri-Mode controller using cables HD Mini-SAS -> SLIMLINE x4 or SLIMLINE x8 -> 2 x SLIMLINE x4 (depending on the controller model, up to 16 drives, additional cables required).
Up to 2 hot-swappable 2.5" SATA3/SAS/NVMe HDD/SSD drives in a cage on the rear panel of the server.
Cable tray connectors: 1 x SLIMLINE x4 connector for SATA/SAS3 drives, 2 x SLIMLINE x4 connectors for NVMe drives.
Storage device connection options:
For SATA drives:
to the integrated SATA-controller of the CPU with the cable SLIMLINE x4 -> SLIMLINE x4 (enabled by default for 2 drives).
For SATA and/or SAS drives:
- to SAS RAID controller or HBA with HD Mini-SAS -> SLIMLINE x4 cable (for 2 drives, additional cable required);
- to the Tri-Mode controller using the HD Mini-SAS -> SLIMLINE x4 or SLIMLINE x8 -> 2 x SLIMLINE x4 cable (depending on the controller model, for 2 drives, an additional cable is required).
Additional StorageUp to two M.2 PCIe 3.0 x4 2242/2260/2280 drives installed in slots on the motherboard.
Up to two or four M.2 PCIe 3.0 x4 2280/22110 drives installed on an expansion card in a PCIe slot.
Up to two M.2 SATA / PCIe 3.0 x4 2280/22110 drives installed on a SAS3408-based expansion card with RAID 0/1 support in a PCIe slot.
Optical StorageNot supported, only external via USB 3.0 port.
Interfaces Front panel: 2 USB 3.0 ports
On the rear panel: DB-15 video connector, RJ-45 1GbE control port, 3 USB 3.0 ports, 2 1GbE RJ-45 network ports, COM port, ID Button with LED
Internal ports: COM port
Video Adapter and GPUIntegrated video controller Aspeed? AST2500 Video Graphic Adapter, 1920x1200@60Hz 32bpp, DDR4 SDRAM
Control PanelControl buttons: Power, Reset, System ID, NMI
Indication: Power LED, ID LED, System Status LED, Drive activity LED, LAN 1/2 Activity LED
Management and MonitoringIntegrated Baseboard Management Controller Aspeed? AST2500, IPMI 2.0 & Redfish
Built-in RJ-45 1GbE remote management port
Fully functional remote control (KVM, Virtual Media over LAN)
GIGABYTE Management Console
GIGABYTE Server Management (GSM)
Supported Operating SystemsWindows Server 2016 (X2APIC/256T not supported)
Windows Server 2019
Windows Server 2022
Red Hat Enterprise Linux 8.3 (x64) or later
SUSE Linux Enterprise Server 12 SP5 (x64) or later
SUSE Linux Enterprise Server 15 SP2 (x64) or later
Ubuntu 18.04.5 LTS (x64) or later
Ubuntu 20.04 LTS (x64) or later
Ubuntu 22.04 LTS (x64) or later
VMware ESXi 6.7 Update3 P03 or later
VMware ESXi 7.0 Update1 or later
Citrix Hypervisor 8.2.0 or later
Power Unit2 x 1200W 80 Plus Platinum redundant hot-swappable power supplies
Power subsystem operating modes: 1+1 Redundant Power, 2+0 Combined Power
Supported technologies:
Cold Redundancy - at a power consumption level of up to 40% of the maximum, only one power supply is used, which increases energy efficiency by approximately 10%.
Smart Crises Management and Protection (SCMP) GIGABYTE patented technology for high-load systems. When the power consumption level is more than 50% of the maximum, in the event of a power supply failure, the system switches to a low-power mode to prevent unplanned shutdown.
Smart Ride Through (SmaRT) - a technology that prevents the system from shutting down during a short-term (up to 10-20 ms) power failure by reducing energy consumption (throttling).
System Cooling4 controlled single-rotor fans 80x80x38 mm with redundancy and hot-swappable capability, 16'300 RPM
1 fan in each power supply
CPU radiator with passive cooling
DimensionsHeight 8.75 cm, width 43.8 cm, depth 66.0 cm
Rack Mount InstallationSlide-out rails for rack mounting
Power Supply Parameters100-240 VAC, 10-4 A, 50-60 Hz
Operating EnvironmentOperating temperature from +10?C to +35?C
Relative humidity from 8% to 80%
Storage temperature from -40?C to +60?C
Relative humidity during storage from 20% to 95%
WarrantyStandard warranty 36 months, 9 x 5, service at the service center