www.team.ru
Поиск
sales@team.ru

GIGABYTE R282-3CA. Technical specifications

ENG | RUS

High-performance, high-density server supporting 3rd Generation Intel Xeon Scalable processors with a maximum TDP of 270W, 2U height
Typical application:
- universal high-performance business application server
- virtual machine platform
- database server
- high-performance storage system
- network services server
- server for 1C

Previous photo Zoom photo Next photo
Please check availability

Platform characteristics R282-3CA

Characteristic  Description
PlatformGIGABYTE R282-3CA Server Platform
Server BoardGIGABYTE Server Board MR92-FS0
One or two 3rd Generation Intel? Xeon? Scalable processors, maximum TDP 270W
Interprocessor interface 11.2 GT/s (3 links)
32 slots for installing DDR4-3200 memory modules
14 SATA ports, 8 PCIe 4.0 x4 ports for NVMe drives, 4 USB 3.0 ports, COM port, IPMI, Dual BIOS
2 PCIe 4.0 x32 slots and 1 PCIe 4.0 x16 slot for installing riser cards, 128 PCIe 4.0 lanes when installing two CPUs
2 slots for installing LAN or RAID mezzanine modules: OCP 3.0 PCIe 4.0 x16, OCP 2.0 Type1 PCIe 3.0 x8
Baseboard Management Controller Aspeed AST2500
Form Factor2U, rack mountable
Processor1 or 2 3rd Generation Intel? Xeon? Scalable Processors
Maximum Thermal Design Power (TDP) -270W per processor (all Xeon Scalable Gen3 dual-socket processors)
Supported processors: Intel Xeon Silver 4300, Gold 5300, Gold 6300, Platinum 8300, except processors with indexes (H), (L), (U), (Q)
Processor socket Socket-P4 LGA4189, Intel Ice Lake architecture,10nm process technology
From 8 to 40 cores and 80 threads per processor, operating frequency from 2.0 GHz to 3.6 GHz
Up to 160 logical CPUs per server with Intel Hyper-Threading Technology
Up to 60 MB L3 cache per processor (1.5 MB per core), 1.25 MB L2 cache per core, 32 KB + 48 KB L1 cache per core
Maximum amount of RAM supported by the processor6TB
DDR4-2667/2933/3200 MT/s memory support (depending on processor model), 4 dual-channel memory controllers (IMC)
Support for Registered and Load reduced ECC memory, including 3DS
Support for Intel? Optane? Persistent Memory 200 Series (Xeon Gold and Platinum only) in Memory Mode and APP Direct Mode
Interprocessor interface UPI 10.4 (2 links) or 11.2 GT/s (3 links),64 PCIe 4.0 lanes (4GB/s per lane), DMI 3.0 (4 lines)
ChipsetIntel C621A Chipset, 20 PCIe 3.0 lanes, 14 SATA ports, 14 USB 2.0, 10 USB 3.0
System MemoryMemory types:
- DDR4 ECC Registered Memory (RDIMM) 1.2V, DDR4 ECC Registered Memory 3DS (RDIMM 3DS) 1.2V
- DDR4 ECC Load Reduced Memory (LRDIMM) 1.2V, DDR4 ECC Load Reduced Memory 3DS (LRDIMM 3DS) 1.2V
- Intel? Optane? Persistent Memory 200 Series (PMEM), 128GB, 256GB, 512GB modules
Maximum RAM (the processor supports a maximum of 6TB of RAM):
- for RDIMM - 2048 GB (32 x 64 GB), for LRDIMM - 4096 GB (32 x 128 GB)
- for RDIMM 3DS - 4096 GB (32 x 128 GB), for LRDIMM 3DS - 8192 GB (32 x 256 GB)
- for PMEM - 8192 GB in Memory Mode, 12 TB in APP Direct Mode (16 x 256 GB DDR4 + 16 x 512 GB PMEM)
Memory operating modes: 2666/2933/3200 MT/s (depending on processor model)
4 dual-channel memory controllers (IMC) integrated into the processor
Total 8 channels per CPU, two memory modules per channel (2 DPC)
Total 16 memory modules per CPU, 32 memory modules per server
Memory subsystem bandwidth 171/188/205 GB/s (2667/2933/3200 MT/s) per CPU
Network AdaptersWithout built-in network adapter. Requires installation of network module in OCP 3.0 slot or network card in expansion slot
Dedicated 1 Gb Ethernet RJ-45 management port
Additionally:
- replaceable network module with installation in the slot on the OCP3.0 PCIe 4.0 x16 motherboard;
- replaceable network module with installation in a slot on the OCP2.0 PCIe 3.0 x8 motherboard;
- up to eight network adapters in standard PCIe 4.0 expansion slots
Expansion Slots Riser card #1, connection toCPU#1:
- 1 PCIe 4.0 x16/x16 Full Height, Half Length slot;
- 2 PCIe 4.0 x8/x8 Full Height, Half Length slots.
Riser card #2, connection toCPU#2:
- 1 PCIe 4.0 x16/x16 or x8/x16 Full Height, Half Length slot, shares 8 PCIe lanes with slot 2;
1 PCIe 4.0 x0/x8 or x8/x8 Full Height, Half Length slot, shares 8 PCIe lanes with slot 1;
1 x16/x16 or x8/x16 PCIe 4.0 Full Height, Half Length slot, shares 8 PCIe lanes with OCP 2.0 connector.
(Only functional when a second processor is installed!)
Riser card #3, connection toCPU#2:
- 2 PCIe 4.0 x8/x8 low-profile, half-length slots.
(Only functional when a second processor is installed!)
PCIe 4.0 x16 OCP 3.0 slot on the motherboard for installing a network module, connecting toCPU#1
PCIe 3.0 x8 OCP 2.0 Type1 slot on the motherboard for installing a network module or SAS module, shares 8 PCIe lanes with slot 3 of Riser Card #2, connecting toCPU#2
(Only works when a second processor is installed!)
Disk Subsystem ControllerIntegrated chipset SATA controller, 8 6Gb/s ports (2 4-port SFF-8654 SLIMLINE x4 connectors):
- support VROC 7.5 RAID 0/1/10/5
Integrated chipset sSATA controller, 6 ports 6Gb/s (1 4-port SFF-8654 SLIMLINE x4 connector, 2 7-Pin SATA connectors with SATA DOM support):
- support VROC 7.5 RAID 0/1/10/5
8 PCIe 4.0 x4 ports for connecting NVMe drives (2 SFF-8654 SLIMLINE x8 connectors from CPU#1, 2 SFF-8654 SLIMLINE x8 connectors from CPU#2)
- support for Intel VMD 2.0, Intel VROC 7.5 RAID 0/1/10/5 (RAID requires Intel VROC Key)
Additionally (selection in the Configurator fields "Disk subsystem controller" and "HBA adapter):
- GIGABYTE SAS module for SAS3 and/or SATA drives to the OCP2.0 PCIe3.0 x8 slot on the motherboard;
- RAID controller, HBA adapter or Tri-Mode controller for SAS3 and/or SATA drives in PCIe 4.0 expansion slots;
- Tri-Mode controller for an alternative option for connecting NVMe drives to PCIe 4.0 expansion slots.
Disk SubsystemUp to 12 hot-swappable 3.5"/2.5" SAS3/SATA3/NVMe Gen4 HDD/SSD drives in a cage on the front of the server.
Cable tray connectors: 3 SLIMLINE x4 connectors for SATA/SAS3 drives, 12 SLIMLINE x4 connectors for NVMe PCIe 4.0 x4 drives.
Storage device connection options:
For SATA drives:
to the integrated SATA controllers of the motherboard with three cables SLIMLINE x4 -> SLIMLINE x4 (enabled by default for 12 drives).
For SATA and/or SAS drives:
- to the GIGABYTE SAS RAID module using SLIMLINE x4 -> SLIMLINE x4 cables (up to 8 drives, using existing cables);
to SAS RAID controller or HBA with HD Mini-SAS -> SLIMLINE x4 cables (up to 12 drives, additional cables required);
- to the Tri-Mode controller with cables 2 x HD Mini-SAS -> 2 x SLIMLINE x4 or SLIMLINE x8 -> 2 x SLIMLINE x4 (depending on the controller model, up to 12 drives, additional cables required).
For NVMe drives:
- to four PCIe 4.0 x4 CPU#1 ports with SLIMLINE x8 -> 2 x SLIMLINE x4 cables (enabled by default for four drives);
- to four PCIe 4.0 x4 CPU#2 ports with SLIMLINE x8 -> 2 x SLIMLINE x4 cables (enabled by default for four drives);
to the Tri-Mode controller or HBA with cables 2 x HD Mini-SAS -> 2 x SLIMLINE x4 or SLIMLINE x8 -> 2 x SLIMLINE x4 (depending on the controller model, up to 4 drives).
Up to 2 hot-swappable 2.5" SAS3/SATA3 HDD/SSD drives in a cage on the rear panel of the server.
Cable tray connectors: 1 x SLIMLINE x4 connector for SATA/SAS3 drives, 2 x SLIMLINE x4 connectors for NVMe PCIe 4.0 x4 drives.
Storage device connection options:
For SATA drives:
- to the integrated SATA controller of the motherboard with a 2 x 7-Pin SATA -> SLIMLINE x4 Cross-Over cable (enabled by default for 2 drives).
For SATA and/or SAS drives:
- to the GIGABYTE SAS RAID module with the SLIMLINE x4 -> SLIMLINE x4 cable (for 2 drives, an additional cable is required);
- to SAS RAID controller or HBA with HD Mini-SAS -> SLIMLINE x4 cable (for 2 drives, additional cable required);
to the Tri-Mode controller with a cable 2 x HD Mini-SAS -> 2 x SLIMLINE x4 or SLIMLINE x8 -> 2 x SLIMLINE x4 (depending on the controller model, for 2 drives, an additional cable is required).
Additional StorageUp to two internal SATA DOM drives installed in the 7-Pin SATA connectors of the integrated sSATA controller on the motherboard.
Support Boot RAID 0/1, Intel VROC 7.5
Up to two or four M.2 PCIe 3.0 x4 2280/22110 drives installed on an expansion card in a PCIe slot.
Up to two M.2 SATA / PCIe 3.0 x4 2280/22110 drives installed on a SAS3408-based expansion card with RAID 0/1 support in a PCIe slot.
Optical StorageNot supported, only external via USB 3.0 port.
Interfaces Front panel: 2 USB 3.0 ports
On the rear panel: DB-15 video connector, RJ-45 1GbE control port, 2 USB 3.0 ports, ID Button with LED
Internal ports: Serial Port
Video Adapter and GPUIntegrated video controller Aspeed? AST2500 Video Graphic Adapter, 1920x1200@60Hz 32bpp, DDR4 SDRAM
It is possible to install an additional video card
Control PanelControl buttons: Power, Reset, System ID, NMI
Indication: Power LED, ID LED, System Status LED, Drive activity LED, LAN 1/2 Activity LED
Management and MonitoringIntegrated Baseboard Management Controller Aspeed? AST2500, IPMI 2.0 & Redfish
Built-in RJ-45 1GbE remote management port
Fully functional remote control (KVM, Virtual Media over LAN)
GIGABYTE Management Console
GIGABYTE Server Management (GSM)
Supported Operating SystemsWindows Server 2016
Windows Server 2019
Windows Server 2022
Red Hat Enterprise Linux 8.2 (x64) or later
Red Hat Enterprise Linux 8.3 (x64) or later
SUSE Linux Enterprise Server 12 SP5 (x64) or later
SUSE Linux Enterprise Server 15 SP2 (x64) or later
Ubuntu 20.04 LTS (x64) or later
Ubuntu 20.04.1 LTS (x64) or later
VMware ESXi 6.7 Update3 P03
VMware ESXi 7.0 Update2
Citrix Hypervisor 8.2.0
Power Unit2 x 1300W 80 Plus Platinum redundant hot-swappable power supplies
Power subsystem operating modes: 1+1 Redundant Power, 2+0 Combined Power
Supported technologies:
Cold Redundancy - at a power consumption level of up to 40% of the maximum, only one power supply is used, which increases energy efficiency by approximately 10%.
Smart Crises Management and Protection (SCMP) GIGABYTE patented technology for high-load systems. When the power consumption level is more than 50% of the maximum, in the event of a power supply failure, the system switches to a low-power mode to prevent unplanned shutdown.
Smart Ride Through (SmaRT) - a technology that prevents the system from shutting down during a short-term (up to 10-20 ms) power failure by reducing energy consumption (throttling).
System Cooling4 controlled single-rotor fans 80x80x38 mm with redundancy and hot-swappable capability, 16'300 RPM
1 fan in each power supply
Passive Cooled CPU Heatsinks
DimensionsHeight 8.75 cm, width 43.8 cm, depth 73.0 cm
Rack Mount InstallationSlide-out rails for rack mounting
Power Supply Parameters100-240 VAC, 12-10 A, 50-60 Hz
Operating EnvironmentOperating temperature from +10?C to +35?C
Relative humidity from 8% to 80%
Storage temperature from -40?C to +60?C
Relative humidity during storage from 20% to 95%
WarrantyStandard warranty 36 months, 9 x 5, service at the service center