GIGABYTE R283-S91-AAJ1. Technical specifications

ENG | RUS

High-performance, high-density dual-processor server based on 4th/5th Generation Intel Xeon Scalable (TDP 350W), 2U height.
Typical application:
- universal high-performance business application server
- virtual machine platform
- database server
- high-performance storage system
- network services server
- server for 1C

Previous photo Zoom photo Next photo
In stock

Platform characteristics R283-S91-AAJ1

Characteristic  Description
PlatformGIGABYTE R283-S91-AAJ1 Server Platform
Server BoardGIGABYTE Server Board MS93-FS0
One or two 4th/5th Generation Intel? Xeon? Scalable processors, maximum TDP 350W
Interprocessor interface 16 GT/s (4 links)
32 slots for installing DDR5-4800/5600 memory modules
16 SATA ports, 4 USB 3.2 Gen1 ports, IPMI, Dual BIOS, Dual BMC Firmware
6 PCIe 5.0 x16 slots for installing riser cards and OCP modules, 160 PCIe 5.0 lanes when installing two CPUs
16 PCIe 5.0 x4 ports for connecting riser cards or NVMe drives (8 MCIO x8 connectors)
Baseboard Management Controller Aspeed AST2600
Form Factor2U, rack mountable
Processor1 or 2 4th/5th Generation Intel? Xeon? Scalable Processors
Maximum Thermal Design Power (TDP) -350W on the processor
Supported processors: Intel Xeon Silver 4400/4500, Gold 5400/5500, Gold 6400/6500, Platinum 8400/8500, MAX 9400 (except processors with index Q)
FCLGA4677 processor socket, Intel Sapphire Rapids/Emerald Rapids architecture, Intel 7 process technology
From 8 to 64 cores and 128 threads per processor, operating frequency from 1.8 GHz to 3.7 GHz
Up to 256 logical CPUs per server with Intel Hyper-Threading Technology
Up to 320 MB L3 cache per processor
Maximum amount of RAM supported by the processor4TB
Supports DDR5-4000/4400/4800/5600 MT/s memory (depending on processor model), eight-channel memory controller (IMC)
Support for Registered ECC memory, including 3DS
Support for Intel? Optane? DC Persistent Memory 300 Series (Crow Pass)
UPI 16 GT/s interprocessor interface (3 or 4 links),80 PCIe 5.0 lanes (8GB/s per lane), DMI 3.0 (4 lines)
ChipsetIntel C741 Chipset, 20 PCIe 3.0 lanes, 24 SATA ports, 14 USB 2.0 / 10 USB 3.0
System MemoryMemory types:
- DDR5 ECC Registered Memory (RDIMM) 1.1V, DDR5 ECC Registered Memory 3DS (RDIMM 3DS) 1.1V
Maximum RAM (the processor supports a maximum of 4TB of RAM):
- for RDIMM - 2048 GB (32 x 64 GB)
- for RDIMM 3DS - 8192 GB (32 x 256 GB)
Memory modes: 4800/5600 MT/s (1 DPC), 4400 MT/s (2DPC)
Integrated 8-channel memory controller (IMC) on the processor
Total 8 channels per CPU, two memory modules per channel (2 DPC)
Total 16 memory modules per CPU, 32 memory modules per server
Memory subsystem bandwidth 307.2 / 358.4 GB/s
Network AdaptersIntegrated network controller Intel Ethernet Controller I350-AM2, 2 ports 1Gb Ethernet RJ-45
Dedicated 1 Gb Ethernet RJ-45 management port
Additionally:
- up to two network modules installed in the OCP 3.0 PCIe 5.0 x16 motherboard slots;
- up to eight network adapters in standard PCIe 5.0 x16 expansion slots
Expansion SlotsRiser Card #1:
- 3 PCIe 5.0 x16/x16 Full Height, Half Length slots, connection toCPU#1
Riser Card #2:
- 3 PCIe 5.0 x16/x16 Full Height, Half Length slots, connection toCPU#2
(Only functional when a second processor is installed!)
Riser Card #3:
2 PCIe 5.0 x8/x16 Low Profile, Half Length slots, connection toCPU#1
Slot #1 PCIe 5.0 x16 OCP 3.0 on the motherboard for installing a network module, connecting toCPU#1
Slot #2 PCIe 5.0 x16 OCP 3.0 on the motherboard for installing a network module, connecting toCPU#2
(Only works when a second processor is installed!)
Disk Subsystem ControllerIntegrated chipset SATA controller, 8 6Gb/s ports (2 4-port SFF-8654 SLIMLINE x4 connectors),not used with port expander:
- support VROC 8.0 RAID 0/1/10/5
Integrated sSATA chipset controller, 8 6Gb/s ports (2 4-port SFF-8654 SLIMLINE x4 connectors),not used with port expander:
- support VROC 8.0 RAID 0/1/10/5
Front disk cage with Broadcom SAS35x24R Expander port expander, 24 ports 12 Gb/s (8 incoming ports, 4 outgoing ports, 12 ports on the cage backplane).
Requires installation of a RAID controller or HBA connected to a front cage port expander to use SATA and/or SAS drives.
4 PCIe 5.0 x4 ports for connecting NVMe drives (2 SFF-TA-1016 MCIO x8 connectors fromCPU#2)
- support for Intel VMD, Intel VROC 8.0 RAID 0/1/10/5 (RAID requires Intel VROC Key)
Additionally (selection in the Configurator fields "Disk subsystem controller" and "HBA adapter):
- RAID controller, HBA adapter or Tri-Mode controller for SAS3 and/or SATA drives via a port expander installed in a PCIe 5.0 expansion slot;
- Tri-Mode controller for an alternative option for connecting NVMe drives to the PCIe 5.0 expansion slot.
Disk SubsystemUp to 12 hot-swappable 3.5"/2.5" SAS3/SATA3/ drivesNVMe Gen4 U.2/U.3 (up to four) HDD/SSD in a basket with a SAS port expander on the front panel of the server.
Connectors on the basket for connecting cables:
- 3 SLIMLINE x4 connectors for SAS3/SATA drives via port expander (2 - IN, 1 - OUT);
4 SLIMLINE x4 connectors for NVMe PCIe 4.0 x4 drives (U.2 or U.3)
Options for connecting SATA and/or SAS drives (via Broadcom SAS35x24R port expander):
to the Tri-Mode RAID controller or HBA with the SLIMLINE x8 -> 2 x SLIMLINE x4 cable (for 12 drives, cable included in the delivery package);
- to the RAID controller or HBA with two cables HD Mini-SAS -> SLIMLINE x4 (for 12 drives, additional cables are required);
Requires installation of a RAID controller or HBA connected to a front cage port expander to use SATA and/or SAS drives.
For NVMe drives:
- to four PCIe 5.0 x4 ports from CPU#2 on the motherboard with two cables MCIO x8 -> 2 x SLIMLINE x4 (connected by default for four drives, bays 9-12);
to the Tri-Mode controller using cables 2 x HD Mini-SAS -> 2 x SLIMLINE x4 or SLIMLINE x8 -> 2 x SLIMLINE x4 (depending on the controller model, up to four drives per controller, an additional cable is required for each pair of drives).
Up to 2 hot-swappable 2.5" SAS3/SATA3 HDD/SSD drives in a cage on the rear panel of the server.
Cable tray connectors: 1 x SLIMLINE x4 connector for SATA/SAS3 drives, 2 x SLIMLINE x4 connectors for NVMe PCIe 4.0 x4 drives.
Storage device connection options:
For SATA and/or SAS drives:
- to the output ports of the front basket port expander with the SLIMLINE x4 -> SLIMLINE x4 cable (enabled by default for 2 drives);
- to the integrated SATA controller of the motherboard using the SLIMLINE x4 -> SLIMLINE x4 cable.
Additional StorageUp to two or four M.2 PCIe 3.0 x4 2280/22110 drives installed on an expansion card in a PCIe slot.
Up to two M.2 SATA / PCIe 4.0 x4 2280/22110 drives installed on a SAS3808-based expansion card with RAID 0/1 support in a PCIe slot.
Optical StorageNot supported, only external via USB 3.2 port.
Interfaces Front panel: 2 USB 3.2 Gen1 ports
On the rear panel: Mini-DP video connector (D-Sub adapter included), RJ-45 1GbE management port, 2 1GbE RJ-45 network ports, 2 USB 3.2 Gen1 ports
Video Adapter and GPUIntegrated video controller Aspeed? AST2600 Video Graphic Adapter, 1920x1200@60Hz 32bpp, DDR4 SDRAM.
It is possible to install an additional video card.
Control PanelOn the front panel:
- control buttons: Power, Reset, System ID, NMI
indication: Power LED, ID LED, System Status LED, Drive activity LED, LAN Activity LED
On the back panel:
- indication: ID LED
Management and MonitoringIntegrated Baseboard Management Controller Aspeed? AST2600, IPMI 2.0 & Redfish
Built-in RJ-45 1GbE remote management port
Fully functional remote control (KVM, Virtual Media over LAN)
GIGABYTE Management Console
GIGABYTE Server Management (GSM)
Supported Operating SystemsCurrent list
Power Unit2 x 2000W 80 Plus Titanium PSUs with redundancy and hot swappability
Power subsystem operating modes: 1+1 Redundant Power, 2+0 Combined Power
Supported technologies:
Cold Redundancy - at a power consumption level of up to 40% of the maximum, only one power supply is used, which increases energy efficiency by approximately 10%.
Smart Crises Management and Protection (SCMP) GIGABYTE patented technology for high-load systems. When the power consumption level is more than 50% of the maximum, in the event of a power supply failure, the system switches to a low-power mode to prevent unplanned shutdown.
Smart Ride Through (SmaRT) - a technology that prevents the system from shutting down during a short-term (up to 10-20 ms) power failure by reducing energy consumption (throttling).
System Cooling4 controlled single-rotor fans 80x80x38 mm with redundancy and hot-swappable capability, 18'300 RPM
1 fan in each power supply
Passive Cooled CPU Heatsinks
DimensionsHeight 8.75 cm, width 43.8 cm, depth 81.5 cm
Rack Mount InstallationSlide-out rails for rack mounting
Power Supply Parameters100-240 VAC, 12-10 A, 50-60 Hz
Operating EnvironmentOperating temperature from +10?C to +35?C
Relative humidity from 8% to 80%
Storage temperature from -40?C to +60?C
Relative humidity during storage from 20% to 95%
WarrantyStandard warranty 36 months, 9 x 5, service at the service center