| Characteristic |
Description |
 |  |
| Platform | GIGABYTE R283-S91-AAJ1 Server Platform |
| Server Board | GIGABYTE Server Board MS93-FS0 One or two 4th/5th Generation Intel? Xeon? Scalable processors, maximum TDP 350W Interprocessor interface 16 GT/s (4 links) 32 slots for installing DDR5-4800/5600 memory modules 16 SATA ports, 4 USB 3.2 Gen1 ports, IPMI, Dual BIOS, Dual BMC Firmware 6 PCIe 5.0 x16 slots for installing riser cards and OCP modules, 160 PCIe 5.0 lanes when installing two CPUs 16 PCIe 5.0 x4 ports for connecting riser cards or NVMe drives (8 MCIO x8 connectors) Baseboard Management Controller Aspeed AST2600 |
| Form Factor | 2U, rack mountable |
| Processor | 1 or 2 4th/5th Generation Intel? Xeon? Scalable Processors Maximum Thermal Design Power (TDP) -350W on the processor Supported processors: Intel Xeon Silver 4400/4500, Gold 5400/5500, Gold 6400/6500, Platinum 8400/8500, MAX 9400 (except processors with index Q) FCLGA4677 processor socket, Intel Sapphire Rapids/Emerald Rapids architecture, Intel 7 process technology From 8 to 64 cores and 128 threads per processor, operating frequency from 1.8 GHz to 3.7 GHz Up to 256 logical CPUs per server with Intel Hyper-Threading Technology Up to 320 MB L3 cache per processor Maximum amount of RAM supported by the processor4TB Supports DDR5-4000/4400/4800/5600 MT/s memory (depending on processor model), eight-channel memory controller (IMC) Support for Registered ECC memory, including 3DS Support for Intel? Optane? DC Persistent Memory 300 Series (Crow Pass) UPI 16 GT/s interprocessor interface (3 or 4 links),80 PCIe 5.0 lanes (8GB/s per lane), DMI 3.0 (4 lines) |
| Chipset | Intel C741 Chipset, 20 PCIe 3.0 lanes, 24 SATA ports, 14 USB 2.0 / 10 USB 3.0 |
| System Memory | Memory types: - DDR5 ECC Registered Memory (RDIMM) 1.1V, DDR5 ECC Registered Memory 3DS (RDIMM 3DS) 1.1V Maximum RAM (the processor supports a maximum of 4TB of RAM): - for RDIMM - 2048 GB (32 x 64 GB) - for RDIMM 3DS - 8192 GB (32 x 256 GB) Memory modes: 4800/5600 MT/s (1 DPC), 4400 MT/s (2DPC) Integrated 8-channel memory controller (IMC) on the processor Total 8 channels per CPU, two memory modules per channel (2 DPC) Total 16 memory modules per CPU, 32 memory modules per server Memory subsystem bandwidth 307.2 / 358.4 GB/s |
| Network Adapters | Integrated network controller Intel Ethernet Controller I350-AM2, 2 ports 1Gb Ethernet RJ-45 Dedicated 1 Gb Ethernet RJ-45 management port Additionally: - up to two network modules installed in the OCP 3.0 PCIe 5.0 x16 motherboard slots; - up to eight network adapters in standard PCIe 5.0 x16 expansion slots |
| Expansion Slots | Riser Card #1: - 3 PCIe 5.0 x16/x16 Full Height, Half Length slots, connection toCPU#1 Riser Card #2: - 3 PCIe 5.0 x16/x16 Full Height, Half Length slots, connection toCPU#2 (Only functional when a second processor is installed!) Riser Card #3: 2 PCIe 5.0 x8/x16 Low Profile, Half Length slots, connection toCPU#1 Slot #1 PCIe 5.0 x16 OCP 3.0 on the motherboard for installing a network module, connecting toCPU#1 Slot #2 PCIe 5.0 x16 OCP 3.0 on the motherboard for installing a network module, connecting toCPU#2 (Only works when a second processor is installed!) |
| Disk Subsystem Controller | Integrated chipset SATA controller, 8 6Gb/s ports (2 4-port SFF-8654 SLIMLINE x4 connectors),not used with port expander: - support VROC 8.0 RAID 0/1/10/5 Integrated sSATA chipset controller, 8 6Gb/s ports (2 4-port SFF-8654 SLIMLINE x4 connectors),not used with port expander: - support VROC 8.0 RAID 0/1/10/5 Front disk cage with Broadcom SAS35x24R Expander port expander, 24 ports 12 Gb/s (8 incoming ports, 4 outgoing ports, 12 ports on the cage backplane). Requires installation of a RAID controller or HBA connected to a front cage port expander to use SATA and/or SAS drives. 4 PCIe 5.0 x4 ports for connecting NVMe drives (2 SFF-TA-1016 MCIO x8 connectors fromCPU#2) - support for Intel VMD, Intel VROC 8.0 RAID 0/1/10/5 (RAID requires Intel VROC Key) Additionally (selection in the Configurator fields "Disk subsystem controller" and "HBA adapter): - RAID controller, HBA adapter or Tri-Mode controller for SAS3 and/or SATA drives via a port expander installed in a PCIe 5.0 expansion slot; - Tri-Mode controller for an alternative option for connecting NVMe drives to the PCIe 5.0 expansion slot. |
| Disk Subsystem | Up to 12 hot-swappable 3.5"/2.5" SAS3/SATA3/ drivesNVMe Gen4 U.2/U.3 (up to four) HDD/SSD in a basket with a SAS port expander on the front panel of the server. Connectors on the basket for connecting cables: - 3 SLIMLINE x4 connectors for SAS3/SATA drives via port expander (2 - IN, 1 - OUT); 4 SLIMLINE x4 connectors for NVMe PCIe 4.0 x4 drives (U.2 or U.3) Options for connecting SATA and/or SAS drives (via Broadcom SAS35x24R port expander): to the Tri-Mode RAID controller or HBA with the SLIMLINE x8 -> 2 x SLIMLINE x4 cable (for 12 drives, cable included in the delivery package); - to the RAID controller or HBA with two cables HD Mini-SAS -> SLIMLINE x4 (for 12 drives, additional cables are required); Requires installation of a RAID controller or HBA connected to a front cage port expander to use SATA and/or SAS drives. For NVMe drives: - to four PCIe 5.0 x4 ports from CPU#2 on the motherboard with two cables MCIO x8 -> 2 x SLIMLINE x4 (connected by default for four drives, bays 9-12); to the Tri-Mode controller using cables 2 x HD Mini-SAS -> 2 x SLIMLINE x4 or SLIMLINE x8 -> 2 x SLIMLINE x4 (depending on the controller model, up to four drives per controller, an additional cable is required for each pair of drives). Up to 2 hot-swappable 2.5" SAS3/SATA3 HDD/SSD drives in a cage on the rear panel of the server. Cable tray connectors: 1 x SLIMLINE x4 connector for SATA/SAS3 drives, 2 x SLIMLINE x4 connectors for NVMe PCIe 4.0 x4 drives. Storage device connection options: For SATA and/or SAS drives: - to the output ports of the front basket port expander with the SLIMLINE x4 -> SLIMLINE x4 cable (enabled by default for 2 drives); - to the integrated SATA controller of the motherboard using the SLIMLINE x4 -> SLIMLINE x4 cable. |
| Additional Storage | Up to two or four M.2 PCIe 3.0 x4 2280/22110 drives installed on an expansion card in a PCIe slot. Up to two M.2 SATA / PCIe 4.0 x4 2280/22110 drives installed on a SAS3808-based expansion card with RAID 0/1 support in a PCIe slot. |
| Optical Storage | Not supported, only external via USB 3.2 port. |
| Interfaces | Front panel: 2 USB 3.2 Gen1 ports On the rear panel: Mini-DP video connector (D-Sub adapter included), RJ-45 1GbE management port, 2 1GbE RJ-45 network ports, 2 USB 3.2 Gen1 ports |
| Video Adapter and GPU | Integrated video controller Aspeed? AST2600 Video Graphic Adapter, 1920x1200@60Hz 32bpp, DDR4 SDRAM. It is possible to install an additional video card. |
| Control Panel | On the front panel: - control buttons: Power, Reset, System ID, NMI indication: Power LED, ID LED, System Status LED, Drive activity LED, LAN Activity LED On the back panel: - indication: ID LED |
| Management and Monitoring | Integrated Baseboard Management Controller Aspeed? AST2600, IPMI 2.0 & Redfish Built-in RJ-45 1GbE remote management port Fully functional remote control (KVM, Virtual Media over LAN) GIGABYTE Management Console GIGABYTE Server Management (GSM) |
| Supported Operating Systems | Current list |
| Power Unit | 2 x 2000W 80 Plus Titanium PSUs with redundancy and hot swappability Power subsystem operating modes: 1+1 Redundant Power, 2+0 Combined Power Supported technologies: Cold Redundancy - at a power consumption level of up to 40% of the maximum, only one power supply is used, which increases energy efficiency by approximately 10%. Smart Crises Management and Protection (SCMP) GIGABYTE patented technology for high-load systems. When the power consumption level is more than 50% of the maximum, in the event of a power supply failure, the system switches to a low-power mode to prevent unplanned shutdown. Smart Ride Through (SmaRT) - a technology that prevents the system from shutting down during a short-term (up to 10-20 ms) power failure by reducing energy consumption (throttling). |
| System Cooling | 4 controlled single-rotor fans 80x80x38 mm with redundancy and hot-swappable capability, 18'300 RPM 1 fan in each power supply Passive Cooled CPU Heatsinks |
| Dimensions | Height 8.75 cm, width 43.8 cm, depth 81.5 cm |
| Rack Mount Installation | Slide-out rails for rack mounting |
| Power Supply Parameters | 100-240 VAC, 12-10 A, 50-60 Hz |
| Operating Environment | Operating temperature from +10?C to +35?C Relative humidity from 8% to 80% Storage temperature from -40?C to +60?C Relative humidity during storage from 20% to 95% |
| Warranty | Standard warranty 36 months, 9 x 5, service at the service center |