| Characteristic |
Description |
 |  |
| Platform | GIGABYTE R283-SF1-AAL1 Server Platform |
| Server Board | GIGABYTE Server Board MSF3-GP0 One or two 4th/5th Generation Intel? Xeon? Scalable processors, maximum TDP 350W Interprocessor interface 16 GT/s (4 links) 32 slots for installing DDR5-4800/5600 memory modules 16 SATA ports, 4 USB 3.2 Gen1 ports, IPMI, Dual BIOS, Dual BMC Firmware PCIe 5.0 x16 slots for installing riser cards and OCP module, 160 PCIe 5.0 lanes when installing two CPUs 16 PCIe 5.0 x4 ports for connecting riser cards or NVMe drives (8 MCIO x8 connectors) Baseboard Management Controller Aspeed AST2600 |
| Form Factor | 2U, rack mountable |
| Processor | 1 or 2 4th/5th Generation Intel? Xeon? Scalable Processors Maximum Thermal Design Power (TDP) -350W on the processor Supported processors: Intel Xeon Silver 4400/4500, Gold 5400/5500, Gold 6400/6500, Platinum 8400/8500, MAX 9400 (except processors with index Q) FCLGA4677 processor socket, Intel Sapphire Rapids/Emerald Rapids architecture, Intel 7 process technology From 8 to 64 cores and 128 threads per processor, operating frequency from 1.8 GHz to 3.7 GHz Up to 256 logical CPUs per server with Intel Hyper-Threading Technology Up to 320 MB L3 cache per processor Maximum amount of RAM supported by the processor4TB Supports DDR5-4000/4400/4800/5600 MT/s memory (depending on processor model), eight-channel memory controller (IMC) Support for Registered ECC memory, including 3DS Support for Intel? Optane? DC Persistent Memory 300 Series (Crow Pass) Interprocessor interface UPI 16/20 GT/s (3 or 4 links),80 PCIe 5.0 lanes (8GB/s per lane), DMI 3.0 (4 lines) |
| Chipset | Intel C741 Chipset, 20 PCIe 3.0 lanes, 24 SATA ports, 14 USB 2.0 / 10 USB 3.0 |
| System Memory | Memory types: - DDR5 ECC Registered Memory (RDIMM) 1.1V, DDR5 ECC Registered Memory 3DS (RDIMM 3DS) 1.1V Maximum RAM (the processor supports a maximum of 4TB of RAM): - for RDIMM - 2048 GB (32 x 64 GB) - for RDIMM 3DS - 8192 GB (32 x 256 GB) Memory modes: 4800/5600 MT/s (1 DPC), 4400 MT/s (2DPC) Integrated 8-channel memory controller (IMC) on the processor Total 8 channels per CPU, two memory modules per channel (2 DPC) Total 16 memory modules per CPU, 32 memory modules per server Memory subsystem bandwidth 307.2 / 358.4 GB/s |
| Network Adapters | Without built-in network adapter. Requires installation of network module in OCP 3.0 slot or network card in expansion slot Dedicated 1 Gb Ethernet RJ-45 management port Additionally: - network module with installation in a slot on the motherboard OCP 3.0 PCIe 5.0 x16; - up to five network adapters in standard PCIe 5.0 x16 expansion slots |
| Expansion Slots | Riser Card #1: - 2 PCIe 5.0 x16/x16 full height, full length, double width slots, connecting toCPU#1 Riser Card #2: - 1 PCIe 5.0 x16/x16 Full Height, Full Length, Double Wight slot, connects toCPU#2 - 1 x PCIe 5.0 x16/x16 Full Height, Half Length slot, connects toCPU#2 (Only functional when a second processor is installed!) Riser Card #3: - 1 PCIe 5.0 x16/x16 Full Height, Full Length, Double Wight slot, connects toCPU#2 (Only works when a second processor is installed!) Slot #1 PCIe 5.0 x16 OCP 3.0 on the motherboard for installing a network module, connecting toCPU#1 |
| Disk Subsystem Controller | Integrated chipset SATA controller, 8 6Gb/s ports (2 4-port SFF-8654 SLIMLINE x4 connectors): - support VROC 8.0 RAID 0/1/10/5 Integrated sSATA controller, 8 6Gb/s ports (2 4-port SFF-8654 SLIMLINE x4 connectors): - support VROC 8.0 RAID 0/1/10/5 16 PCIe 5.0 x4 ports for connecting NVMe drives (4 SFF-TA-1016 MCIO x8 connectors from CPU#1, 4 SFF-TA-1016 MCIO x8 connectors from CPU#2) - support for Intel VMD, Intel VROC 8.0 RAID 0/1/10/5 (RAID requires Intel VROC Key) Additionally (selection in the Configurator fields "Disk subsystem controller" and "HBA adapter): RAID controller, HBA adapter or Tri-Mode controller for SAS3 and/or SATA drives in PCIe 5.0 expansion slots; - Tri-Mode controller for an alternative option for connecting NVMe drives to PCIe 5.0 expansion slots. |
| Disk Subsystem | Up to 16 hot-swappable 2.5" drivesSAS4/SATA3/NVMe Gen5 U.2/U.3HDD/SSD into the basket on the front panel of the server. Connectors on the basket for connecting cables: - 4 SLIMLINE x4 connectors for SAS4/SATA drives; 16 MCIO x4 slots for NVMe PCIe 5.0 x4 drives (U.2 or U.3) Storage device connection options: For SATA drives: - to the integrated Primary SATA controller of the motherboard with two cables SLIMLINE x4 -> SLIMLINE x4 (connected by default for eight drives, bays 1-8). - to the integrated Secondary SATA controller of the motherboard with the cable SLIMLINE x4 -> SLIMLINE x4 (connected by default for four drives, bays 9-16). For SATA and/or SAS drives: to a SAS RAID controller or HBA using HD Mini-SAS -> SLIMLINE x4 cables (up to 16 drives, an additional cable is required for every four drives); - to the Tri-Mode controller using cables HD Mini-SAS -> SLIMLINE x4 or SLIMLINE x8 -> 2 x SLIMLINE x4 (depending on the controller model, up to 16 drives, additional cables required). For NVMe drives: to six PCIe 5.0 x4 ports from CPU#1 on the motherboard with three cables MCIO x8 -> 2 x MCIO x4 (connected by default for six drives, bays 5-10); - to six PCIe 5.0 x4 ports from CPU#2 on the motherboard with three cables MCIO x8 -> 2 x MCIO x4 (connected by default for six drives, bays 11-16); - to two free PCIe 5.0 x4 ports from CPU#1 on the motherboard with a MCIO x8 -> 2 x MCIO x4 cable (up to 2 drives); - to two free PCIe 5.0 x4 ports from CPU#2 on the motherboard with a MCIO x8 -> 2 x MCIO x4 cable (up to 2 drives); - to the Tri-Mode controller using SLIMLINE x8 -> 2 x MCIO x4 cables (up to four drives per controller, an additional cable is required for each pair of drives). |
| Additional Storage | Up to two or four M.2 PCIe 3.0 x4 2280/22110 drives installed on an expansion card in a PCIe slot. Up to two M.2 SATA / PCIe 4.0 x4 2280/22110 drives installed on a SAS3808-based expansion card with RAID 0/1 support in a PCIe slot. |
| Optical Storage | Not supported, only external via USB 3.2 port. |
| Interfaces | Front panel: 2 USB 3.2 Gen1 ports On the rear panel: Mini-DP video connector (D-Sub adapter included), RJ-45 1GbE control port, 2 USB 3.2 Gen1 ports |
| Video Adapter and GPU | Integrated video controller Aspeed? AST2600 Video Graphic Adapter, 1920x1200@60Hz 32bpp, DDR4 SDRAM. It is possible to install up to four full-size, double-width graphics accelerators with a power consumption of up to 300W each. |
| Control Panel | On the front panel: - control buttons: Power, Reset, System ID, NMI indication: Power LED, ID LED, System Status LED, Drive activity LED, LAN Activity LED On the back panel: - indication: ID LED |
| Management and Monitoring | Integrated Baseboard Management Controller Aspeed? AST2600, IPMI 2.0 & Redfish Built-in RJ-45 1GbE remote management port Fully functional remote control (KVM, Virtual Media over LAN) GIGABYTE Management Console GIGABYTE Server Management (GSM) |
| Supported Operating Systems | Current list |
| Power Unit | 2 x 2700W 80 Plus Titanium PSUs with redundancy and hot swappability Power subsystem operating modes: 1+1 Redundant Power, 2+0 Combined Power Supported technologies: Cold Redundancy - at a power consumption level of up to 40% of the maximum, only one power supply is used, which increases energy efficiency by approximately 10%. Smart Crises Management and Protection (SCMP) GIGABYTE patented technology for high-load systems. When the power consumption level is more than 50% of the maximum, in the event of a power supply failure, the system switches to a low-power mode to prevent unplanned shutdown. Smart Ride Through (SmaRT) - a technology that prevents the system from shutting down during a short-term (up to 10-20 ms) power failure by reducing energy consumption (throttling). |
| System Cooling | 4 controlled single-rotor fans 80x80x38 mm with redundancy and hot-swappable capability, 18'300 RPM 1 controlled single rotor fan 40x40x28 mm, 34'300 RPM 1 fan in each power supply Passive Cooled CPU Heatsinks |
| Dimensions | Height 8.75 cm, width 43.8 cm, depth 81.5 cm |
| Rack Mount Installation | Slide-out rails for rack mounting |
| Power Supply Parameters | 100-240 VAC, 12-10 A, 50-60 Hz |
| Operating Environment | Operating temperature from +10?C to +35?C Relative humidity from 8% to 80% Storage temperature from -40?C to +60?C Relative humidity during storage from 20% to 95% |
| Warranty | Standard warranty 36 months, 9 x 5, service at the service center |