www.team.ru
Поиск
sales@team.ru

GIGABYTE R283-SF1-AAL1. Technical specifications

ENG | RUS

High-performance, high-density dual-processor server based on 4th/5th Generation Intel Xeon Scalable (TDP 350W), 2U height.
It is possible to install four graphics accelerators (GPU) or double-width video cards.
Typical application:
- virtual machine platform
- network services server
- database server
- hybrid/cloud storage
- AI and Machine Learning
- high-performance computing using GPU

Previous photo Zoom photo Next photo
In stock

Platform characteristics R283-SF1-AAL1

Characteristic  Description
PlatformGIGABYTE R283-SF1-AAL1 Server Platform
Server BoardGIGABYTE Server Board MSF3-GP0
One or two 4th/5th Generation Intel? Xeon? Scalable processors, maximum TDP 350W
Interprocessor interface 16 GT/s (4 links)
32 slots for installing DDR5-4800/5600 memory modules
16 SATA ports, 4 USB 3.2 Gen1 ports, IPMI, Dual BIOS, Dual BMC Firmware
PCIe 5.0 x16 slots for installing riser cards and OCP module, 160 PCIe 5.0 lanes when installing two CPUs
16 PCIe 5.0 x4 ports for connecting riser cards or NVMe drives (8 MCIO x8 connectors)
Baseboard Management Controller Aspeed AST2600
Form Factor2U, rack mountable
Processor1 or 2 4th/5th Generation Intel? Xeon? Scalable Processors
Maximum Thermal Design Power (TDP) -350W on the processor
Supported processors: Intel Xeon Silver 4400/4500, Gold 5400/5500, Gold 6400/6500, Platinum 8400/8500, MAX 9400 (except processors with index Q)
FCLGA4677 processor socket, Intel Sapphire Rapids/Emerald Rapids architecture, Intel 7 process technology
From 8 to 64 cores and 128 threads per processor, operating frequency from 1.8 GHz to 3.7 GHz
Up to 256 logical CPUs per server with Intel Hyper-Threading Technology
Up to 320 MB L3 cache per processor
Maximum amount of RAM supported by the processor4TB
Supports DDR5-4000/4400/4800/5600 MT/s memory (depending on processor model), eight-channel memory controller (IMC)
Support for Registered ECC memory, including 3DS
Support for Intel? Optane? DC Persistent Memory 300 Series (Crow Pass)
Interprocessor interface UPI 16/20 GT/s (3 or 4 links),80 PCIe 5.0 lanes (8GB/s per lane), DMI 3.0 (4 lines)
ChipsetIntel C741 Chipset, 20 PCIe 3.0 lanes, 24 SATA ports, 14 USB 2.0 / 10 USB 3.0
System MemoryMemory types:
- DDR5 ECC Registered Memory (RDIMM) 1.1V, DDR5 ECC Registered Memory 3DS (RDIMM 3DS) 1.1V
Maximum RAM (the processor supports a maximum of 4TB of RAM):
- for RDIMM - 2048 GB (32 x 64 GB)
- for RDIMM 3DS - 8192 GB (32 x 256 GB)
Memory modes: 4800/5600 MT/s (1 DPC), 4400 MT/s (2DPC)
Integrated 8-channel memory controller (IMC) on the processor
Total 8 channels per CPU, two memory modules per channel (2 DPC)
Total 16 memory modules per CPU, 32 memory modules per server
Memory subsystem bandwidth 307.2 / 358.4 GB/s
Network AdaptersWithout built-in network adapter. Requires installation of network module in OCP 3.0 slot or network card in expansion slot
Dedicated 1 Gb Ethernet RJ-45 management port
Additionally:
- network module with installation in a slot on the motherboard OCP 3.0 PCIe 5.0 x16;
- up to five network adapters in standard PCIe 5.0 x16 expansion slots
Expansion SlotsRiser Card #1:
- 2 PCIe 5.0 x16/x16 full height, full length, double width slots, connecting toCPU#1
Riser Card #2:
- 1 PCIe 5.0 x16/x16 Full Height, Full Length, Double Wight slot, connects toCPU#2
- 1 x PCIe 5.0 x16/x16 Full Height, Half Length slot, connects toCPU#2
(Only functional when a second processor is installed!)
Riser Card #3:
- 1 PCIe 5.0 x16/x16 Full Height, Full Length, Double Wight slot, connects toCPU#2
(Only works when a second processor is installed!)
Slot #1 PCIe 5.0 x16 OCP 3.0 on the motherboard for installing a network module, connecting toCPU#1
Disk Subsystem ControllerIntegrated chipset SATA controller, 8 6Gb/s ports (2 4-port SFF-8654 SLIMLINE x4 connectors):
- support VROC 8.0 RAID 0/1/10/5
Integrated sSATA controller, 8 6Gb/s ports (2 4-port SFF-8654 SLIMLINE x4 connectors):
- support VROC 8.0 RAID 0/1/10/5
16 PCIe 5.0 x4 ports for connecting NVMe drives (4 SFF-TA-1016 MCIO x8 connectors from CPU#1, 4 SFF-TA-1016 MCIO x8 connectors from CPU#2)
- support for Intel VMD, Intel VROC 8.0 RAID 0/1/10/5 (RAID requires Intel VROC Key)
Additionally (selection in the Configurator fields "Disk subsystem controller" and "HBA adapter):
RAID controller, HBA adapter or Tri-Mode controller for SAS3 and/or SATA drives in PCIe 5.0 expansion slots;
- Tri-Mode controller for an alternative option for connecting NVMe drives to PCIe 5.0 expansion slots.
Disk Subsystem Up to 16 hot-swappable 2.5" drivesSAS4/SATA3/NVMe Gen5 U.2/U.3HDD/SSD into the basket on the front panel of the server.
Connectors on the basket for connecting cables:
- 4 SLIMLINE x4 connectors for SAS4/SATA drives;
16 MCIO x4 slots for NVMe PCIe 5.0 x4 drives (U.2 or U.3)
Storage device connection options:
For SATA drives:
- to the integrated Primary SATA controller of the motherboard with two cables SLIMLINE x4 -> SLIMLINE x4 (connected by default for eight drives, bays 1-8).
- to the integrated Secondary SATA controller of the motherboard with the cable SLIMLINE x4 -> SLIMLINE x4 (connected by default for four drives, bays 9-16).
For SATA and/or SAS drives:
to a SAS RAID controller or HBA using HD Mini-SAS -> SLIMLINE x4 cables (up to 16 drives, an additional cable is required for every four drives);
- to the Tri-Mode controller using cables HD Mini-SAS -> SLIMLINE x4 or SLIMLINE x8 -> 2 x SLIMLINE x4 (depending on the controller model, up to 16 drives, additional cables required).
For NVMe drives:
to six PCIe 5.0 x4 ports from CPU#1 on the motherboard with three cables MCIO x8 -> 2 x MCIO x4 (connected by default for six drives, bays 5-10);
- to six PCIe 5.0 x4 ports from CPU#2 on the motherboard with three cables MCIO x8 -> 2 x MCIO x4 (connected by default for six drives, bays 11-16);
- to two free PCIe 5.0 x4 ports from CPU#1 on the motherboard with a MCIO x8 -> 2 x MCIO x4 cable (up to 2 drives);
- to two free PCIe 5.0 x4 ports from CPU#2 on the motherboard with a MCIO x8 -> 2 x MCIO x4 cable (up to 2 drives);
- to the Tri-Mode controller using SLIMLINE x8 -> 2 x MCIO x4 cables (up to four drives per controller, an additional cable is required for each pair of drives).
Additional StorageUp to two or four M.2 PCIe 3.0 x4 2280/22110 drives installed on an expansion card in a PCIe slot.
Up to two M.2 SATA / PCIe 4.0 x4 2280/22110 drives installed on a SAS3808-based expansion card with RAID 0/1 support in a PCIe slot.
Optical StorageNot supported, only external via USB 3.2 port.
Interfaces Front panel: 2 USB 3.2 Gen1 ports
On the rear panel: Mini-DP video connector (D-Sub adapter included), RJ-45 1GbE control port, 2 USB 3.2 Gen1 ports
Video Adapter and GPUIntegrated video controller Aspeed? AST2600 Video Graphic Adapter, 1920x1200@60Hz 32bpp, DDR4 SDRAM.
It is possible to install up to four full-size, double-width graphics accelerators with a power consumption of up to 300W each.
Control PanelOn the front panel:
- control buttons: Power, Reset, System ID, NMI
indication: Power LED, ID LED, System Status LED, Drive activity LED, LAN Activity LED
On the back panel:
- indication: ID LED
Management and MonitoringIntegrated Baseboard Management Controller Aspeed? AST2600, IPMI 2.0 & Redfish
Built-in RJ-45 1GbE remote management port
Fully functional remote control (KVM, Virtual Media over LAN)
GIGABYTE Management Console
GIGABYTE Server Management (GSM)
Supported Operating SystemsCurrent list
Power Unit2 x 2700W 80 Plus Titanium PSUs with redundancy and hot swappability
Power subsystem operating modes: 1+1 Redundant Power, 2+0 Combined Power
Supported technologies:
Cold Redundancy - at a power consumption level of up to 40% of the maximum, only one power supply is used, which increases energy efficiency by approximately 10%.
Smart Crises Management and Protection (SCMP) GIGABYTE patented technology for high-load systems. When the power consumption level is more than 50% of the maximum, in the event of a power supply failure, the system switches to a low-power mode to prevent unplanned shutdown.
Smart Ride Through (SmaRT) - a technology that prevents the system from shutting down during a short-term (up to 10-20 ms) power failure by reducing energy consumption (throttling).
System Cooling4 controlled single-rotor fans 80x80x38 mm with redundancy and hot-swappable capability, 18'300 RPM
1 controlled single rotor fan 40x40x28 mm, 34'300 RPM
1 fan in each power supply
Passive Cooled CPU Heatsinks
DimensionsHeight 8.75 cm, width 43.8 cm, depth 81.5 cm
Rack Mount InstallationSlide-out rails for rack mounting
Power Supply Parameters100-240 VAC, 12-10 A, 50-60 Hz
Operating EnvironmentOperating temperature from +10?C to +35?C
Relative humidity from 8% to 80%
Storage temperature from -40?C to +60?C
Relative humidity during storage from 20% to 95%
WarrantyStandard warranty 36 months, 9 x 5, service at the service center