High-performance dual-processor server with support for processorsAMD EPYC 9004 with a maximum TDP of 400W, height 2U
Typical application:
- universal high-performance business application server
- virtual machine platform
- AI, machine learning
- applications for working with graphics
- network services server
- server for 1C

Previous photo Zoom photo Next photo
Please check availability

Platform characteristics R283-Z91-AAD1

Characteristic  Description
PlatformServer platform GIGABYTE R283-Z91-AAD1
Server BoardGIGABYTE Server Board MZ93-FS0
One or two AMD EPYC 9004 processors (Genoa/Bergamo), maximum TDP 400W
Interprocessor interface 512 GB/s (64 PCIe 5.0 Lines)
24 slots for installing DDR5-4800 memory modules
16 SATA ports, 4 USB 3.2 Gen1 ports, IPMI, 3 M.2 PCIe 2280/22110 slots
4 PCIe 5.0 x16 slots for installing riser cards, 2 PCIe 5.0 x16 OCP 3.0 slots, 128 PCIe 5.0 lanes when installing two CPUs
4 PCIe 5.0 x4 ports for connecting NVMe drives from CPU#2 (2 Mini Cool Edge IO x8 connectors)
Baseboard Management Controller Aspeed AST2600
Form Factor2U, rack mountable
Processor1 or 2 AMD EPYC 9004 processors with a maximum TDP of 400W each, support for AMD 3D V-Cache Technology
For each processor:
Processor socket Socket SP5 (LGA 6096), AMD Zen 4 (Genoa/Bergamo) architecture, 5 nm process technology
Up to 128 cores, 256 threads, operating frequency up to 4.1 GHz (maximum 4.4 GHz in Boost mode)
Up to 1152 MB L3 cache per CPU, per core: 1024 KB L2, 32 KB (I)+ 32 KB (D) L1
Support for AMD Infinity Guard, AMD Infinity Architecture technologies
128 PCIe 5.0 lanes per CPU, 64 of which are used as interprocessor interface
Supports ECC DDR5-4800 memory, up to 6 TB per CPU (up to 12 TB total), integrated 12-channel memory controller
ChipsetSystem on Chip (SoC) (the chipset is built into the processor)
System MemoryMemory types:
- DDR5 ECC Registered Memory (RDIMM) 1.1V, DDR5 ECC Registered Memory 3DS (RDIMM 3DS) 1.1V
Maximum RAM (the processor supports a maximum of 6TB of RAM):
- for RDIMM - 1536 GB (24 x 64 GB)
- for RDIMM 3DS - 6144 GB (24 x 256 GB)
Memory modes: 4800 MT/s (1 DPC)
Integrated 12-channel memory controller (IMC) on the processor
Total 12 channels per CPU, one memory module per channel (1 DPC)
Total 12 memory modules per CPU, 24 memory modules per server
Memory subsystem bandwidth 460.8 GB/s
Network AdaptersIntegrated network controller Intel Ethernet Controller I350-AM2, 2 ports 1Gb Ethernet RJ-45
Dedicated 1 Gb Ethernet RJ-45 management port
Additionally:
- up to two network modules with installation in the connectors on the OCP 3.0 motherboardPCIe 5.0 x16;
- up to six network adapters in standard expansion slotsPCIe 5.0 x16
Expansion SlotsRiser Card #1:
- 1 slotPCIe 5.0 x16/x16 Full Height, Half Length, Connect toCPU#1
Riser Card #2:
- 2 slotsPCIe 5.0 x16/x16 and x8/x18 Full Height, Half Length, Connect toCPU#1
Riser Card #3:
- 1 slotPCIe 5.0 x16/x16 Full Height, Half Length, Connect toCPU#2
(Only works when a second processor is installed!)
Riser Card #4:
- 2 slotsPCIe 5.0 x16/x16 and x8/x16 Full Height, Half Length, Connect toCPU#2
(Only functional when a second processor is installed!)
SlotPCIe 5.0 x16 OCP 3.0 on the motherboard for installing a network module, connecting toCPU#1
SlotPCIe 5.0 x16 OCP 3.0 on the motherboard for installing a network module, connecting toCPU#2
(Only works when a second processor is installed!)
Disk Subsystem ControllerWithout integrated SATA controller
Requires installation of a RAID controller with connection to a port expander to use SATA and/or SAS drives.
Broadcom SAS35x24 Expander Front Enclosure Port Expander, 24 SAS3 12 Gb/s Ports, 8 In, 16 Out, 3 SLIMLINE x4 (2 IN/1 OUT)
4 PCIe 5.0 x4 ports for NVMe drives via SFF-TA-1016 MCIO x8 connector and two MCIO x4 connectors on the motherboard fromCPU#1;
Additionally (selection in the Configurator fields "Disk subsystem controller" and "HBA adapter):
- RAID controller, HBA adapter or Tri-Mode controller for SAS3 and/or SATA drives (via expander) in PCIe 5.0 expansion slot
- Tri-Mode controller for an alternative option for connecting NVMe drives to PCIe 5.0 expansion slots.
Disk SubsystemUp to 12 hot-swappable 3.5"/2.5" SAS3/SATA3 HDD/SSD drives in a cage with port expander on the front panel of the server, including up to 4 NVMe drives
Connectors on the basket for connecting cables:
- 2 SLIMLINE x4 connectors for SAS3/SATA drives via built-in port expander, 1 SLIMLINE x4 connector for connecting the rear cage;
- 4 SLIMLINE x4 connectors for NVMe drives.
Storage device connection options:
For SATA and/or SAS drives:
- to the SAS RAID controller or HBA with two HD Mini-SAS -> SLIMLINE x4 cables (cables included in the delivery package);
- to the Tri-Mode controller using cables 2 x HD Mini-SAS -> 2 x SLIMLINE x4 or SLIMLINE x8 -> 2 x SLIMLINE x4 (depending on the controller model, additional cables are required).
For NVMe drives:
- to four PCIe 5.0 x4 ports via MCIO x8 connectors, 2 x MCIO x4 fromCPU#1 cable MCIO x8 -> 2 x SLIMLINE x4 and two cables MCIO x4 -> SLIMLINE x4, (connected for 4 drives, bays 9-12);
to the Tri-Mode controller using cables 2 x HD Mini-SAS -> 2 x SLIMLINE x4 or SLIMLINE x8 -> 2 x SLIMLINE x4 (depending on the controller model, up to four drives per controller, an additional cable is required for each pair of drives).
Up to 2 hot-swappable 2.5" SAS3/SATA3 SSD drives in a cage on the rear of the server.
Cable tray connectors: 1 x SLIMLINE x4 connector for SATA/SAS3 drives, 2 x SLIMLINE x4 connectors for NVMe PCIe 4.0 x4 drives.
Storage device connection options:
For SATA and/or SAS drives:
- to the outgoing ports of the SAS port expander with the SLIMLINE x4 -> SLIMLINE x4 cable (enabled by default for 2 drives).
Additional StorageUp to three M.2 2280/22110 drives installed in a slot on the motherboard:
- PCIe 3.0 x4 from CPU#1
- PCIe 3.0 x4 from CPU#2
- PCIe 3.0 x2 from CPU#2
Up to two or four M.2 PCIe 3.0 x4 2280/22110 drives installed on an expansion card in a PCIe slot.
Up to two M.2 SATA / PCIe 4.0 x4 2280/22110 drives installed on a SAS3808-based expansion card with RAID 0/1 support in a PCIe slot.
Optical StorageNot supported, only external via USB 3.2 port.
Interfaces Front panel: 2 USB 3.2 Gen1 ports
On the rear panel: Mini-DP video connector (D-Sub adapter included), RJ-45 1GbE management port, 2 1GbE RJ-45 network ports, 2 USB 3.2 Gen1 ports
Video Adapter and GPUIntegrated video controller Aspeed? AST2600 Video Graphic Adapter, 1920x1200@60Hz 32bpp, DDR4 SDRAM
It is possible to install an additional video card
Control PanelOn the front panel:
- control buttons: Power, Reset, System ID, NMI
indication: Power LED, ID LED, System Status LED, Drive activity LED, LAN Activity LED
On the back panel:
- indication: ID LED
Management and MonitoringIntegrated Baseboard Management Controller Aspeed? AST2600, IPMI 2.0 & Redfish
Built-in RJ-45 1GbE remote management port
Fully functional remote control (KVM, Virtual Media over LAN)
GIGABYTE Management Console
GIGABYTE Server Management (GSM)
Supported Operating SystemsCurrent list
Power Unitx 1600W 80 Plus Platinum PSUs with redundancy and hot swappability
Power subsystem operating modes: 1+1 Redundant Power, 2+0 Combined Power
Supported technologies:
Cold Redundancy - at a power consumption level of up to 40% of the maximum, only one power supply is used, which increases energy efficiency by approximately 10%.
Smart Crises Management and Protection (SCMP) GIGABYTE patented technology for high-load systems. When the power consumption level is more than 50% of the maximum, in the event of a power supply failure, the system switches to a low-power mode to prevent unplanned shutdown.
Smart Ride Through (SmaRT) - a technology that prevents the system from shutting down during a short-term (up to 10-20 ms) power failure by reducing energy consumption (throttling).
System Cooling4 controlled single-rotor fans 80x80x38 mm with redundancy and hot-swappable capability, 18'300 RPM
1 fan in each power supply
Passive Cooled CPU Heatsinks
DimensionsHeight 8.7 cm, width 43.8 cm, depth 81.5 cm
Rack Mount InstallationSlide-out rails for rack mounting
Power Supply Parameters100-240 VAC, 12-10 A, 50-60 Hz
Operating EnvironmentOperating temperature from +10?C to +35?C
Relative humidity from 8% to 80%
Storage temperature from -40?C to +60?C
Relative humidity during storage from 20% to 95%
WarrantyStandard warranty 36 months, 9 x 5, service at the service center