www.team.ru
Поиск
sales@team.ru

GIGABYTE R284-A90-AAL1. Technical specifications [EOL]

ENG | RUS

High-performance, high-density dual-processor server based on Intel Xeon 6P Processors (TDP 500W), 2U height.
Typical application:
- universal high-performance business application server
- virtual machine platform
- database server
- high-performance storage system
- network services server
AI, analytics, Big data
- cloud computing

Previous photo Zoom photo Next photo

Platform characteristics R284-A90-AAL1

Characteristic  Description
PlatformGIGABYTE R284-A90-AAL1 Server Platform
Computing Modules High Performance Computing (HPC)
- Internet of Things (IoT)
- server for 1C
Server BoardGIGABYTE Server Board MA94-FS0
One or two Intel? Xeon? 6 processors (6900P), maximum TDP 500W
Interprocessor interface 24 GT/s (6 lines)
24 slots for installing DDR5-6400 RDIMM or DDR5-8800 MRDIMM memory modules
2 PCIe 5.0 x4 slots for M.2 drives, 4 USB 3.2 Gen1 ports, IPMI, Dual BIOS, Dual BMC Firmware
4 PCIe 5.0 x16 slots for installing riser cards and OCP modules, 184 PCIe 5.0 lanes when installing two CPUs
28 PCIe 5.0 x4 ports for connecting riser cards or NVMe drives (14 MCIO x8 connectors)
Baseboard Management Controller Aspeed AST2600
Form Factor2U, rack mountable
Processor1 or 2 Intel? Xeon? 6 Processors (6900P CPU with P-Cores)
Maximum Thermal Design Power (TDP) -500W on the processor
Supported Processors: Intel Xeon 6 Processors with P-Cores (6900P Series)
FCLGA7529 (BR) processor socket, Intel Granite Rapids architecture, Intel 3 process technology
From 72 to 128 cores and 256 threads per processor, operating frequency from 2.0 GHz to 2.7 GHz
Up to 512 logical CPUs per server with Intel Hyper-Threading Technology
Up to 504 MB L3 cache per processor
Maximum amount of RAM supported by the processor3TB
Supports DDR5-6400 RDIMM, DDR5-6400 RDIMM 3DS, DDR5-8800 MRDIMM (Multiplexer Combined Ranks DIMM) memory
12-channel memory controller (IMC)
UPI 24 GT/s (6 links) interprocessor interface,96 PCIe 5.0 lanes (8GB/s per lane)
ChipsetSystem on Chip (SoC) (the chipset is built into the processor)
System MemoryMemory types:
- DDR5 ECC Registered Memory (RDIMM) 1.1V
- DDR5 ECC Registered Memory 3DS (RDIMM 3DS) 1.1V
- DDR5 ECC Multiplexer Combined Ranks Registered DIMM (MRDIMM) 1.1V
Maximum RAM (the processor supports a maximum of 3TB of RAM):
- for RDIMM - 3072 GB (24 x 128 GB)
- for RDIMM 3DS - 6144 GB (24 x 256 GB)
- for MRDIMM - 6144 GB (24 x 256 GB)
Memory modes: 6400 MT/s (RDIMM), 8800 MT/s (MRDIMM)
Integrated 12-channel memory controller (IMC) on the processor
Total 12 channels per CPU, one memory module per channel (1 DPC)
Total 12 memory modules per CPU, 24 memory modules per server
Memory subsystem bandwidth 614 (RDIMM) / 845 (MRDIMM) GB/s
Network AdaptersIntegrated network controller Intel Ethernet Controller I350-AM2, 2 ports 1Gb Ethernet RJ-45
Dedicated 1 Gb Ethernet RJ-45 management port
Additionally:
- up to two network modules installed in the OCP 3.0 PCIe 5.0 x16 motherboard slots;
- up to five network adapters in standard PCIe 5.0 x16 expansion slots
Expansion SlotsRiser Card #1:
- 2 PCIe 5.0 x16/x16 Full Height, Half Length slots, connection toCPU#1
Riser Card #2:
2 PCIe 5.0 x16/x16 Full Height, Half Length slots, connection toCPU#2
(Only functional when a second processor is installed!)
Riser Card #3:
- 1 PCIe 5.0 x16/x16 Low Profile, Half Length slot, connection toCPU#1
Slot #1 PCIe 5.0 x16 OCP 3.0 on the motherboard for installing a network module, connecting toCPU#1
Slot #2 PCIe 5.0 x16 OCP 3.0 on the motherboard for installing a network module, connecting toCPU#2
(Only works when a second processor is installed!)
Disk Subsystem ControllerIntegrated into CPU#1 SATA controller, 2 x 6Gb/s ports (via M.2 drive slot)
12 PCIe 5.0 x4 ports for connecting NVMe drives (2 SFF-TA-1016 MCIO x8 connectors from CPU#1, 4 SFF-TA-1016 MCIO x8 connectors from CPU#2)
- support for Intel VMD, Intel VROC 8.0 RAID 0/1/10/5 (RAID requires Intel VROC Key)
2 x PCIe 5.0 x4 from CPU#1 for M.2 2280/22110 drives
- support for Intel VMD, Intel VROC 8.0 RAID 0/1 (RAID requires Intel VROC Key)
Additionally (selection in the Configurator fields "Disk subsystem controller" and "HBA adapter):
- RAID controller, HBA adapter or Tri-Mode controller for SAS4 and/or SATA drives in PCIe 5.0 expansion slots;
- Tri-Mode controller for an alternative option for connecting NVMe drives to PCIe 5.0 expansion slots.
Disk Subsystem Up to 12 hot-swappable 3.5"/2.5" drivesSAS4/SATA3/NVMe Gen5 U.2/U.3HDD/SSD into the basket on the front panel of the server.
Connectors on the basket for connecting cables:
- 3 SLIMLINE x4 connectors for storage devicesSAS4/SATA;
- 12 MCIO x4 slots for storage devicesNVMe Gen5 PCIe 5.0 x4 (U.2 or U.3)
Storage device connection options:
For SATA and/or SAS4 drives:
- to a SAS RAID controller or HBA using HD Mini-SAS -> SLIMLINE x4 cables (up to 12 drives, an additional cable is required for every four drives);
- to the Tri-Mode controller using cables HD Mini-SAS -> SLIMLINE x4 or SLIMLINE x8 -> 2 x SLIMLINE x4 (depending on the controller model, up to 12 drives, additional cables required).
For NVMe drives:
- to 4 PCIe 5.0 x4 ports from CPU#1 on the motherboard with two cables MCIO x8 -> 2 x MCIO x4 (connected by default for 4 drives, bays 1-4);
- to 8 PCIe 5.0 x4 ports from CPU#2 on the motherboard with four cables MCIO x8 -> 2 x MCIO x4 (connected by default for 6 drives, bays 5-12);
- to the Tri-Mode controller using SLIMLINE x8 -> 2 x MCIO x4 cables (up to four drives per controller, an additional cable is required for each pair of drives).
Up to 2 hot-swappable 2.5" drivesSAS4/SATA3 SSD in the cage on the rear panel of the server.
Cable tray connectors: 1 x SLIMLINE x4 connector for SATA drives/SAS4 2 MCIO x4 slots for NVMe drivesPCIe 5.0 x4.
Storage device connection options:
For SATA drives:
- to the integrated SATA controller CPU#1 with the cable SLIMLINE x4 -> SLIMLINE x4 (enabled by default for 2 drives);
For SATA and/or SSD drivesSAS4:
- to SAS RAID controller or HBA with HD Mini-SAS -> SLIMLINE x4 cable (for 2 drives, additional cable required);
- to the Tri-Mode controller using the cable HD Mini-SAS -> SLIMLINE x4 or SLIMLINE x8 -> 2 x SLIMLINE x4 (depending on the controller model, for 2 drives, an additional cable is required).
Additional StorageUp to two M.2 PCIe 5.0 x4 2280/22110 drives installed in motherboard slots, RAID 0/1 support (VROC key required)
Up to two or four M.2 PCIe 3.0 x4 2280/22110 drives installed on an expansion card in a PCIe slot, RAID 0/1/10/5 support (VROC key required)
Up to two M.2 SATA / PCIe 4.0 x4 2280/22110 drives installed on a SAS3808-based expansion card with RAID 0/1 support in a PCIe slot
Optical StorageNot supported, only external via USB 3.2 port.
Interfaces Front panel: 2 USB 3.2 Gen1 ports
On the rear panel: Mini-DP video connector (D-Sub adapter included), RJ-45 1GbE management port, 2 1GbE RJ-45 network ports, 2 USB 3.2 Gen1 ports
Video Adapter and GPUIntegrated video controller Aspeed? AST2600 Video Graphic Adapter, 1920x1200@60Hz 32bpp, DDR4 SDRAM.
Installation of additional video cards is possible.
Control PanelOn the front panel:
- control buttons: Power, Reset, System ID, NMI
indication: Power LED, ID LED, System Status LED, Drive activity LED, LAN Activity LED
On the back panel:
- indication: ID LED
Management and MonitoringIntegrated Baseboard Management Controller Aspeed? AST2600, IPMI 2.0 & Redfish
Built-in RJ-45 1GbE remote management port
Fully functional remote control (KVM, Virtual Media over LAN)
GIGABYTE Management Console
GIGABYTE Server Management (GSM)
Supported Operating SystemsCurrent list
Power Unit2 x 2700W 80 Plus Titanium PSUs with redundancy and hot swappability
Power subsystem operating modes: 1+1 Redundant Power, 2+0 Combined Power
Supported technologies:
Cold Redundancy - at a power consumption level of up to 40% of the maximum, only one power supply is used, which increases energy efficiency by approximately 10%.
Smart Crises Management and Protection (SCMP) GIGABYTE patented technology for high-load systems. When the power consumption level is more than 50% of the maximum, in the event of a power supply failure, the system switches to a low-power mode to prevent unplanned shutdown.
Smart Ride Through (SmaRT) - a technology that prevents the system from shutting down during a short-term (up to 10-20 ms) power failure by reducing energy consumption (throttling).
System Cooling4 controlled single-rotor fans 80x80x56 mm with redundancy and hot-swappable capability, 15'500 RPM
1 fan in each power supply
Passive Cooled CPU Heatsinks
DimensionsHeight 8.75 cm, width 43.8 cm, depth 81.5 cm
Rack Mount InstallationSlide-out rails for rack mounting
Power Supply Parameters100-240 VAC, 12-10 A, 50-60 Hz
Operating EnvironmentOperating temperature from +10?C to +35?C
Relative humidity from 8% to 80%
Storage temperature from -40?C to +60?C
Relative humidity during storage from 20% to 95%
WarrantyStandard warranty 36 months, 9 x 5, service at the service center