| Characteristic |
Description |
 |  |
| Platform | GIGABYTE R284-A94-AAL1 Server Platform |
| Computing Modules | High Performance Computing (HPC) - Internet of Things (IoT) - server for 1C |
| Server Board | GIGABYTE Server Board MA94-FS0 One or two Intel? Xeon? 6 processors (6900P), maximum TDP 500W Interprocessor interface 24 GT/s (6 lines) 24 slots for installing DDR5-6400 RDIMM or DDR5-8800 MRDIMM memory modules 2 PCIe 5.0 x4 slots for M.2 drives, 4 USB 3.2 Gen1 ports, IPMI, Dual BIOS, Dual BMC Firmware 4 PCIe 5.0 x16 slots for installing riser cards and OCP modules, 184 PCIe 5.0 lanes when installing two CPUs 28 PCIe 5.0 x4 ports for connecting riser cards or NVMe drives (14 MCIO x8 connectors) Baseboard Management Controller Aspeed AST2600 |
| Form Factor | 2U, rack mountable |
| Processor | 1 or 2 Intel? Xeon? 6 Processors (6900P CPU with P-Cores) Maximum Thermal Design Power (TDP) -500W on the processor Supported Processors: Intel Xeon 6 Processors with P-Cores (6900P Series) FCLGA7529 (BR) processor socket, Intel Granite Rapids architecture, Intel 3 process technology From 72 to 128 cores and 256 threads per processor, operating frequency from 2.0 GHz to 2.7 GHz Up to 512 logical CPUs per server with Intel Hyper-Threading Technology Up to 504 MB L3 cache per processor Maximum amount of RAM supported by the processor3TB Supports DDR5-6400 RDIMM, DDR5-6400 RDIMM 3DS, DDR5-8800 MRDIMM (Multiplexer Combined Ranks DIMM) memory 12-channel memory controller (IMC) UPI 24 GT/s (6 links) interprocessor interface,96 PCIe 5.0 lanes (8GB/s per lane) |
| Chipset | System on Chip (SoC) (the chipset is built into the processor) |
| System Memory | Memory types: - DDR5 ECC Registered Memory (RDIMM) 1.1V - DDR5 ECC Registered Memory 3DS (RDIMM 3DS) 1.1V - DDR5 ECC Multiplexer Combined Ranks Registered DIMM (MRDIMM) 1.1V Maximum RAM (the processor supports a maximum of 3TB of RAM): - for RDIMM - 3072 GB (24 x 128 GB) - for RDIMM 3DS - 6144 GB (24 x 256 GB) - for MRDIMM - 6144 GB (24 x 256 GB) Memory modes: 6400 MT/s (RDIMM), 8800 MT/s (MRDIMM) Integrated 12-channel memory controller (IMC) on the processor Total 12 channels per CPU, one memory module per channel (1 DPC) Total 12 memory modules per CPU, 24 memory modules per server Memory subsystem bandwidth 614 (RDIMM) / 845 (MRDIMM) GB/s |
| Network Adapters | Integrated network controller Intel Ethernet Controller I350-AM2, 2 ports 1Gb Ethernet RJ-45 Dedicated 1 Gb Ethernet RJ-45 management port Additionally: - up to two network modules installed in the OCP 3.0 PCIe 5.0 x16 motherboard slots; - up to seven network adapters in standard PCIe 5.0 x16 expansion slots |
| Expansion Slots | Riser Card #1: - 3 PCIe 5.0 x16/x16 Full Height, Half Length slots, connection toCPU#1 Riser Card #2: - 3 PCIe 5.0 x16/x16 Full Height, Half Length slots, connection toCPU#2 (Only functional when a second processor is installed!) Riser Card #3: - 1 PCIe 5.0 x16/x16 Low Profile, Half Length slot, connection toCPU#1 Slot #1 PCIe 5.0 x16 OCP 3.0 on the motherboard for installing a network module, connecting toCPU#1 Slot #2 PCIe 5.0 x16 OCP 3.0 on the motherboard for installing a network module, connecting toCPU#2 (Only works when a second processor is installed!) |
| Disk Subsystem Controller | Requires installation of a RAID controller or HBA connected to a front cage port expander to use SATA and/or SAS drives. Front disk cage with Broadcom SAS4x32 Expander port expander, 32 ports 24 Gb/s (8 incoming ports, 12 outgoing ports, 12 ports on the cage backplane). PCIe 5.0 x4 ports for connecting NVMe drives (4 SFF-TA-1016 MCIO x8 connectors from CPU#2) - support for Intel VMD, Intel VROC 8.0 RAID 0/1/10/5 (RAID requires Intel VROC Key) 2 x PCIe 5.0 x4 from CPU#1 for M.2 2280/22110 drives - support for Intel VMD, Intel VROC 8.0 RAID 0/1 (RAID requires Intel VROC Key) 1 x PCIe 5.0 x2 from CPU#1 for M.2 2280 drive Additionally (selection in the Configurator fields "Disk subsystem controller" and "HBA adapter): - RAID controller, HBA adapter or Tri-Mode controller for SAS4 and/or SATA drives in PCIe 5.0 expansion slots; - Tri-Mode controller for an alternative option for connecting NVMe drives to PCIe 5.0 expansion slots. |
| Disk Subsystem | Up to 12 hot-swappable 3.5"/2.5" drivesSAS4/SATA3 HDD/SSD in a basket with a port expander on the front panel of the server, including up to 4 drivesNVMe Gen5 U.2/U.3 Connectors on the basket for connecting cables: 5 SLIMLINE x4 connectors for storage devicesSAS4/SATA via port expander (2 - IN, 3 - OUT); - 4 MCIO x4 connectors for storage devicesNVMe Gen5 PCIe 5.0 x4 (U.2 or U.3) Storage device connection options: For SATA and/or SAS4 drives: - to a SAS RAID controller or HBA with two HD Mini-SAS -> SLIMLINE x4 cables (up to 12 drives, two additional cables required); - to the Tri-Mode controller via cable 2 x HD Mini-SAS -> 2 x SLIMLINE x4 (up to 12 drives, additional cable required); - to the Tri-Mode controller with a SLIMLINE x8 -> 2 x SLIMLINE x4 cable (up to 12 drives, cable included in the delivery set). For NVMe drives: - to 4 PCIe 5.0 x4 ports from CPU#2 on the motherboard with two cables MCIO x8 -> 2 x MCIO x4 (connected by default for 4 drives, bays 9-12); to the Tri-Mode controller using SLIMLINE x8 -> 2 x MCIO x4 cables (up to four drives, an additional cable is required for each pair of drives). Up to 2 hot-swappable 2.5" drivesSAS4/SATA3/NVMe Gen5 U.2/U.3 SSD in the basket on the back of the server. Cable tray connectors: 1 x SLIMLINE x4 connector for SATA drives/SAS4 2 MCIO x4 slots for NVMe drivesPCIe 5.0 x4. Storage device connection options: For SATA and/or SSD drivesSAS4: - to the output ports of the front basket port expander with the SLIMLINE x4 -> SLIMLINE x4 cable (enabled by default for 2 drives); For NVMe drives: - to 2 free PCIe 5.0 x4 ports from CPU#2 on the motherboard with a MCIO x8 -> 2 x MCIO x4 cable (additional cable required); - to the Tri-Mode controller via SLIMLINE x8 -> 2 x MCIO x4 cable (up to two drives, additional cable required). |
| Additional Storage | Up to two M.2 PCIe 5.0 x4 2280/22110 drives installed in motherboard slots, RAID 0/1 support (VROC key required) One M.2 PCIe 5.0 x2 2280 drive installed in the slot on the motherboard Up to two or four M.2 PCIe 3.0 x4 2280/22110 drives installed on an expansion card in a PCIe slot, RAID 0/1/10/5 support (VROC key required) Up to two M.2 SATA / PCIe 4.0 x4 2280/22110 drives installed on a SAS3808-based expansion card with RAID 0/1 support in a PCIe slot |
| Optical Storage | Not supported, only external via USB 3.2 port. |
| Interfaces | Front panel: 2 USB 3.2 Gen1 ports On the rear panel: Mini-DP video connector (D-Sub adapter included), RJ-45 1GbE management port, 2 1GbE RJ-45 network ports, 2 USB 3.2 Gen1 ports |
| Video Adapter and GPU | Integrated video controller Aspeed? AST2600 Video Graphic Adapter, 1920x1200@60Hz 32bpp, DDR4 SDRAM. Installation of additional video cards is possible. |
| Control Panel | On the front panel: - control buttons: Power, Reset, System ID, NMI indication: Power LED, ID LED, System Status LED, Drive activity LED, LAN Activity LED On the back panel: - indication: ID LED |
| Management and Monitoring | Integrated Baseboard Management Controller Aspeed? AST2600, IPMI 2.0 & Redfish Built-in RJ-45 1GbE remote management port Fully functional remote control (KVM, Virtual Media over LAN) GIGABYTE Management Console GIGABYTE Server Management (GSM) |
| Supported Operating Systems | Current list |
| Power Unit | 2 x 2700W 80 Plus Titanium PSUs with redundancy and hot swappability Power subsystem operating modes: 1+1 Redundant Power, 2+0 Combined Power Supported technologies: Cold Redundancy - at a power consumption level of up to 40% of the maximum, only one power supply is used, which increases energy efficiency by approximately 10%. Smart Crises Management and Protection (SCMP) GIGABYTE patented technology for high-load systems. When the power consumption level is more than 50% of the maximum, in the event of a power supply failure, the system switches to a low-power mode to prevent unplanned shutdown. Smart Ride Through (SmaRT) - a technology that prevents the system from shutting down during a short-term (up to 10-20 ms) power failure by reducing energy consumption (throttling). |
| System Cooling | 4 controlled single-rotor fans 80x80x56 mm with redundancy and hot-swappable capability, 15'500 RPM 1 fan in each power supply Passive Cooled CPU Heatsinks |
| Dimensions | Height 8.75 cm, width 43.8 cm, depth 81.5 cm |
| Rack Mount Installation | Slide-out rails for rack mounting |
| Power Supply Parameters | 100-240 VAC, 12-10 A, 50-60 Hz |
| Operating Environment | Operating temperature from +10?C to +35?C Relative humidity from 8% to 80% Storage temperature from -40?C to +60?C Relative humidity during storage from 20% to 95% |
| Warranty | Standard warranty 36 months, 9 x 5, service at the service center |