HPE P40424-B21 base configuration is used
in the server HPE ProLiant DL380 Gen10.

Previous photo Zoom photo Next photo
Please check availability

Platform characteristics P40424-B21

Characteristic  Description
Base ConfigurationHPE ProLiant DL380 Gen10, part number P40424-B21
Form Factor2U, rack mountable
CPU1 Intel Xeon Gold 6234 processor: 8 cores, 24.75 MB L3 cache, 3.3 GHz operating frequency, 3 UPI 10.4 GT/s channels, 2FMA, 130 W TDP.
Maximum number of processors per server - 2, 64 logical CPUs per system (in Hyper-Threading mode).
Maximum RAM frequency supported by the processor, 2933 MHz.
Maximum amount of RAM supported by the processor, 1024 MB.
ChipsetIntel C621 Series Chipset
RAMPreinstalled 32 GB memory: 1 HPE 32GB (1x32GB) Dual Rank x8 DDR4-2933 CAS-21-21-21 Registered Memory Kit
Supported memory types:
HPE SmartMemory DDR4 Registered DIMM (RDIMM) - up to 24 modules
HPE SmartMemory DDR4 Load Reduced DIMM (LRDIMM) - up to 24 modules
Maximum RAM 2048 GB (16x128 GB) for LRDIMM, 1536 GB (24x64 GB) for RDIMM
Six-channel memory controller integrated into the CPU: 24 slots per server, 12 slots per CPU, 2 modules per channel
Memory operating frequency 2933 MHz
Maximum memory subsystem bandwidth 140 GB/s per processor
Support for HPE SmartMemory, Advanced ECC, Online Spare technologies
Disk subsystemInstalled basket (Bay-3:
Up to 8 Hot Plug 2.5" SFF SAS/SATA HDD/SSD hot-swappable drives, connected to P408i-a SAS module
Additional baskets (optional in Bay-2andBay-1, possible options):
- Enclosure for 8 Hot Plug 2.5" SFF SAS/SATA HDD/SSD hot-swappable drives (RAID controller required)
- Enclosure for 8 Hot Plug 2.5" SFF SAS/SATA or 6 SAS/SATA + 2 NVMe hot-swappable drives (RAID controller and Riser card with 1 NVMe port required)
- Enclosure for 8 Hot Plug 2.5" SFF NVMe hot-swappable drives (Riser card with 4 NVMe ports, CPU2, High-Perf Fans required)
Additional enclosure (only in the Bay-1):
- Hot Plug 2.5" SFF SAS/SATA HDD/SSD or NVMe hot-swappable drive cage (requires Universal Media bay and 1-port NVMe riser card)
Additional rear panel cages for Riser-1 and Riser-2:
- Rear 2-drive cage for SFF SAS/SATA + x16 FH in Riser 1 / 2 (HPE DL38X Gen10 2SFF SAS/SATA Riser Kit)
Additional rear panel cage for Riser-3:
- 2-drive cage for SFF SAS/SATA (HPE DL38X Gen10 2SFF Front NVMe or Front/Rear SAS/SATA Kit)
Installed drives: no
Total up to 30 2.5" SFF SAS/SATA HDD/SSD drives, including up to 20 NVMe drives.
Disk subsystem controllerIntegrated RAID controller HPE Smart Array Embedded Software RAID S100i SR Controller
14 SATA 6Gb/s ports, RAID 0/1/10/5 support (Software RAID), Zero Memory, 2 ports are used for M.2 drives in the Riser card (optional)
Additionally in the connector on the motherboard:
RAID module HPE Smart Array E208i-a SR Gen10 ( 8 Int Lanes/No Cache) 12G SAS Modular Controller, RAID 0/1/10/5/JBOD
RAID module HPE Smart Array P408i-a SR Gen10 ( 8 Int Lanes/2GB Cache) 12G SAS Modular Controller, RAID 0/1/10/5/50/6/60/JBOD
RAID-module HPE Smart Array P816i-a SR Gen10 (16 Int 4GB Cache+Smart) 12G SAS Modular Controller, RAID 0/1/10/5/50/6/60/JBOD, Smart Cache
Additionally in PCIe slots:
Raid-controller HPE Smart Array E208i-p SR Gen10 (8 Int Lanes/No Cache) 12G SAS PCIe Plug-in Controller, RAID 0/1/10/5/JBOD
Raid-controller HPE Smart Array E208e-p SR Gen10 (8 Ext Lanes/No Cache) 12G SAS PCIe Plug-in Controller, RAID 0/1/10/5/JBOD
HPE Smart Array Raid Controller P408i-p SR Gen10 ( 8 Int Lanes/2GB Cache) 12G SAS PCIe Plug-in Controller, RAID 0/1/10/5/50/6/60/JBOD
HPE Smart Raid Controller Array P408e-p SR Gen10 (8 Ext Lanes/4GB Cache) 12G SAS PCIe Plug-in Controller, RAID 0/1/10/5/50/6/60/JBOD
Raid controller HPE Smart Array P824i-p MR Gen10 (24 Int Lanes/4GB Cache+CacheCade) 12G SAS PCIe Plug-in Controller, RAID 0/1/10/5/50/6/60/JBOD
Port Expander 24 SFF SAS/SATA for Riser-1/Slot-3 for 24 internal ports 12Gb
Network controllerHPE Ethernet 10Gb 2-port FLR-SFP+ BCM57414 Adapter Replacement I/O Module
1GbE Management Port (Dedicated iLO connector)
Additional network adapters in PCIe slots
Expansion slotsThree bays for installing riser cards,
Possible riser card options for the Riser-1bay (connected to CPU1):
- Riser card for 3 PCIe 3.0 slots: x8 FHHL, x16 FHFL, x8 FHHL, 2 M.2 SATA 2280 connectors (installed by default);
- Riser card for 2 PCIe 3.0 slots: x16 FHFL, x16 FHFL (slots 1 and 2);
- Riser card for 2 PCIe 3.0 slots: x16 FHFL, x16 FHFL (slots 2 and 3, for double-width GPUs);
- 4-port riser card for connecting up to 8 NVMe drives in a cage in Box-3;
- Riser card for 1 PCIe 3.0 x16 FHHL slot and a cage for 2 2.5" SFF SAS/SATA Hot-Swap drives;
Possible Riser Card Options for the Riser-2 bay. font-style: normal;">(connects to CPU2, requires a second processor):
- 3-slot PCIe 3.0 riser card: x8 FHHL, x16 FHFL, x8 FHHL;
- 3-slot PCIe 3.0 riser card: x8 FHHL, x8 FHHL, x8 FHHL, 1 port for connecting 2 NVMe drives in a cage in the Universal Media Bay;
- 2-slot PCIe 3.0 riser card: x16 FHFL, x16 FHFL (slots 1 and 2);
- 2-slot PCIe 3.0 riser card: x16 FHFL, x16 FHFL (slots 2 and 3, for double-wide GPUs);
- 4-port riser card for connecting up to 8 NVMe drives in basket in the Box-2 compartment;
- Riser card for 1 PCIe 3.0 x16 FHHL slot and a basket for 2 2.5" SFF SAS/SATA Hot-Swap drives;
Possible options for riser cards for the Riser-3bay (connection to CPU2, a second processor is required):
- Riser card for 2 PCIe 3.0 slots: x8 FHHL, x8 FHHL;
- Riser card for 1 PCIe 3.0 slot: x16 FHHL;
- Riser card for 2 NVMe ports for connecting up to 2 NVMe drives in the basket in the Universal Media Bay.
- instead of a riser card, it is possible to install a basket for 2 SFF SAS/SATA drives (HPE DL38X Gen10 2SFF Front NVMe or Front/Rear SAS/SATA Kit)
Optical storageDVD-RW Optical Drive (Optional)
Requires installation of Universal Media Bay in Bay-1
InterfacesOn the front panel: 1 USB 3.0 port, iLO Front Service Port
Additional when installing Universal Media Bay: Display Port, 2 USB 2.0 connectors.
On the rear panel: 2 USB 3.0 ports, DB-15 video connector, 4 GbE RJ-45 ports, 1GbE RJ-45 management port, serial port (optional).
Internal ports: Micro SD Slot, 2 USB 3.0 ports.
Video adapterIntegrated Matrox G200 video standard, 1280 x 1024 (32 bpp), 1920 x 1200 (16 bpp)
Up to 5 additional video cards or graphic accelerators.
Power Unitx 800W Platinum-level power supply (94%)
Additional second power supply for redundancy with hot-swappable capability
Cooling4 hot-swappable, redundant, managed system fans on 1-socket configurations
6 hot-swappable, redundant, managed system fans on 2-socket configurations
Optional: High-Performance Cooling (required on configurations with NVMe drives or GPUs)
Supported Operating SystemsWindows Server 2019: Essentials, Standard, Datacenter
Windows Server 2016: Essentials, Standard, Datacenter
Windows Server 2012 R2: Essentials, Standard, Datacenter
Microsoft Hyper-V Server: 2012 R2, 2016 & 2019
VMware vSphere 6.0 U3, 6.5 U2 & 6.7 U1
ClearVM: 7.6 & 8.0
Red Hat Enterprise Linux (RHEL) 7.6 w/ Kbase
SUSE Linux Enterprise Server (SLES) 12 SP4 and 15 SP1 (includes Xen)
Rack mount installationHPE 2U Small Form Factor Easy Install Rail Kit
Cable management for slide rails
Optional:
- HPE 2U SFF Ball Bearing Rail Kit
- Cable management for slide rails
- Front bezel tamper evident cover
Built-in controlsHPE iLO (HPE Integrated Lights-Out) 4GB NAND, Firmware HPE iLO5 - status monitoring, alerts and reports, remote management
UEFI - secure server configuration and boot in accordance with the industry standard Unified Extensible Firmware Interface (UEFI)
HPE RESTful API - application developer interface
Intelligent Provisioning - a tool for automated deployment of server infrastructure
Embedded Remote Support - built-in remote support tools that provide automatic transmission of information about hardware events to HP service departments
BIOSHPE Server Unified Extensible Firmware Interface (UEFI)
DimensionsHeight 8.73 cm, Width 44.55 cm, Depth 67.94 cm
WeightMinimum 15 kg, maximum 23 kg
Power supply100/240 VAC, 6.7/3.3 A, 50/60 Hz
Operating EnvironmentOperating temperature from +10°C to +35°C
Storage temperature from -30°C to +60°C
Humidity no more than 90%
Noise levelIdle - 31 dBa
Under load - 31 dBa
Warranty1 year warranty, service center