| Characteristic |
Description |
 |  | | Platform | Server platform Intel Server System M50CYP1UR212 |
| Server Board | Intel Server Board M50CYP2SB1U One or two 3rd Generation Intel® Xeon® Scalable processors Interprocessor interface 11.2 GT/s (3 links) 10 SATA ports, 8 PCIe 4.0 x4 ports for NVMe, 2 M.2 PCIe 3.0 x4/SATA ports, 6 USB ports, 2 COM ports 3 PCIe 4.0 slots for installing riser cards, 124 PCIe 4.0 lanes when installing two CPUs |
| Form Factor | 1U, rack mountable |
| Processor | 1 or 2 3rd Generation Intel® Xeon® Scalable Processors Maximum Thermal Design Power (TDP) -205W per processor (platform limitation) Supported processors: Intel Xeon Silver 4300, Gold 5300, Gold 6300, Platinum 8300, except processors with indexes (H), (L), (U), (Q) Dual Socket-P4 LGA4189 processor socket, Intel Ice Lake architecture,10nm process technology From 8 to 40 cores and 80 threads per processor, operating frequency from 2.0 GHz to 3.6 GHz Up to 160 logical CPUs per server with Intel Hyper-Threading Technology Up to 60 MB L3 cache per processor (1.5 MB per core), 1.25 MB L2 cache per core, 32 KB + 48 KB L1 cache per core The maximum amount of RAM supported by the processor is 6TB Supports DDR4-2667/2933/3200 MT/s memory, 4 dual-channel memory controllers (IMC) Support for Registered and Load reduced ECC memory, including 3DS Supports Intel® Optane™ Persistent Memory 200 Series (Xeon Gold and Platinum only) in Memory Mode, APP Direct Mode Interprocessor interface UPI 10.4 (2 links) or 11.2 GT/s (3 links),64 PCIe 4.0 lanes (4GB/s per lane), DMI 3.0 (4 lines) |
| Chipset | Intel C621A Chipset, 20 PCIe 3.0 lanes, up to 14 SATA ports, 14 USB 2.0, 10 USB 3.0, management port |
| System Memory | Memory types: - DDR4 ECC Registered Memory (RDIMM) 1.2V, DDR4 ECC Registered Memory 3DS (RDIMM 3DS) 1.2V - DDR4 ECC Load Reduced Memory (LRDIMM) 1.2V, DDR4 ECC Load Reduced Memory 3DS (LRDIMM 3DS) 1.2V - Intel® Optane™ Persistent Memory 200 Series (PMEM), 128GB, 256GB, 512GB modules Maximum RAM (the processor supports a maximum of 6TB of RAM): for RDIMM - 2048 GB (32 x 64 GB), for LRDIMM - 4096 GB (32 x 128 GB) - for RDIMM 3DS - 4096 GB (32 x 128 GB), for LRDIMM 3DS - 8192 GB (32 x 256 GB) - for PMEM - 8192 GB in Memory Mode, 12 TB in APP Direct Mode (16 x 256 GB DDR4 + 16 x 512 GB PMEM) Memory operating modes: 2666/2933/3200 MT/s (depending on processor model) dual-channel memory controllers (IMC) integrated into the processor Total 8 channels per CPU, two memory modules per channel (2 DPC) Total 16 memory modules per CPU, 32 memory modules per server Memory subsystem bandwidth 171/188/205 GB/s (2667/2933/3200 MT/s) per CPU |
| Network Adapters | Dedicated 1 Gb Ethernet RJ-45 management port Replacement Intel I/O module (one of) into OCP 3.0 bay via motherboard connector: - Intel Ethernet Network Adapter X710-T2L OCP 3.0, Dual port, RJ45, 10 GbE - Intel Ethernet Network Adapter X710 OCP 3.0, Quad port DA SFP+, 10 GbE Intel Ethernet Network Adapter E810-XXVDA2 OCP 3.0, Dual port, SFP28, 10/25 GbE - Intel Ethernet Network Adapter E810-CQDA2 OCP 3.0, Dual port, QSFP28, 10/25/50/100 GbE Additionally - up to three network adapters in standard PCIe 4.0 expansion slots (2 x16 slots, 1 x8 slot) |
| Expansion Slots | PCIe 4.0 x16 OCP 3.0 slot on the motherboard for installing a network module Riser card #1 (installed in the server): - 1 PCIe 4.0 x16/x16 Low Profile, Half Length slot, connection toCPU#1 Riser card #2 (option 1, option): - 1 PCIe 4.0 x16/x16 Low Profile, Half Length slot, connection toCPU#2 Riser card #2 (option 2): - 1 PCIe 4.0 x16/x16 Low Profile, Half Length slot, connection toCPU#2 - 1 PCIe 4.0 x8/x8 Low Profile, Half Length slot, connection toCPU#2 Riser card #3(optional): - 2 PCIe 4.0 SLIMLINE x8 slots for connecting 4 NVMe drives Riser card slots #2 and riser card slot #3 are only functional when a second processor is installed! |
| Disk Subsystem Controller | Integrated chipset SATA controller, 8 6Gb/s ports (2 4-port Mini-SAS HD connectors): - support VROC 7.5 RAID 0/1/10/5 Integrated sSATA controller into the chipset, 2 M.2 ports for 2280/22110 SATA or PCIe 3.0 x4 drives VROC 7.5 RAID 0/1 support 8 PCIe 4.0 SLIMLINE x4 ports on motherboard for connecting 8 NVMe drives (4 ports from CPU#1, 4 ports from CPU#2) - support for Intel VMD 2.0, Intel VROC 7.5 RAID 0/1/10/5 (requires Intel VROC Key activation key) Additionally (selection in the Configurator fields "Disk subsystem controller" and "HBA adapter): - Intel RAID module for SAS3 and/or SATA drives (requires Interposer Card for installation) - RAID controller, HBA adapter or Tri-Mode controller for SAS3 and/or SATA drives - Riser card #3 with two PCIe 4.0 SLIMLINE x8 ports for connecting 4 NVMe drives Intel or LSI Tri-Mode controller for alternative NVMe drive connectivity |
| Disk Subsystem | Up to 12 hot-swappable 2.5" SAS3/SATA3 HDD/SSD or 2.5" NVMe PCIe 4.0/3.0 x4 SSD drives in the front panel cage Drives of different types (SAS/SATA or NVMe) must be installed in groups of 1 to 4 drives (3 groups in total) Connectors on the basket for connecting cables: 3 HD Mini-SAS 12Gb/s connectors (4 lines) for SAS3/SATA drives (12 drives) - 6 SLIMLINE x8 slots for NVMe drives (12 drives) Storage connection options For SATA drives: - to the integrated SATA controller of the motherboard with a cable HD Mini-SAS -> HD Mini-SAS (maximum 8 drives) For SATA and/or SAS drives: - to the Intel SAS RAID module (installed on the Interposer Card adapter board) with HD Mini-SAS -> HD Mini-SAS cables - to SAS RAID controller or HBA with HD Mini-SAS -> HD Mini-SAS cables to the LSI Tri-Mode controller with LSI HD Mini-SAS -> HD Mini-SAS or SLIMLINE x8 -> 2 x HD Mini SAS cables (depending on the controller model) For NVMe drives: - to 8 PCIe 4.0 SLIMLINE x4 ports of the motherboard with cables 2 x SLIMLINE x4 -> SLIMLINE x8 (up to 8 drives) - to 2 PCIe 4.0 SLIMLINE x8 riser card ports #3 with SLIMLINE x8 -> SLIMLINE x8 cables (up to 4 drives) - to the Intel Tri-Mode controller with SLIMLINE x8 -> SLIMLINE x8 cables - to the LSI Tri-Mode controller with LSI SLIMLINE x8 -> SLIMLINE x8 cables |
| Additional Storage | Up to two internal M.2 PCIe 3.0 x4 or SATA 2280/22110 drives in motherboard slots Support Boot RAID 0/1, Intel VROC 7.5 |
| Optical Storage | Not supported, only external via USB port |
| Interfaces | Front panel: 1 USB 3.0, 1 USB 2.0 Rear panel: DB-15 video connector, RJ-45 serial port A, RJ-45 1GbE management port, 3 USB 3.0 ports Internal ports: Type-A USB 2.0, DH-10 Serial Port B |
| Video Adapter and GPU | Integrated 2D video controller, 128MB DDR4 Memory It is possible to install an additional video card |
| Control Panel | Control buttons: Power, Reset, System ID, NMI Indication: Power LED, System Status LED, Drive activity LED, System ID LED |
| Management and Monitoring | Integrated Baseboard Management Controller, IPMI 2.0 & Redfish Intel Server Management Software Support Intel Node Manager Support Support for Intel Advanced Management Technology Built-in RJ-45 1GbE remote management port Fully functional remote control (KVM, Virtual Media over LAN) Advanced System Management Key (optional) required |
| Power Unit | or 2 power supplies 1300W or 1600W 80 Plus Titanium(the platform is supplied without a power supply) Power subsystem operating modes: 1+0, 1+1 Redundant Power, 2+0 Combined Power |
| System Cooling | 8 dual-rotor 40x40x38mm system fans with redundancy and hot-swappable capability 1 fan in each power supply CPU radiator with passive cooling |
| Dimensions | Height 4.3 cm, width 43.8 cm, depth 78.1 cm |
| Rack Mount Installation | Slide-out rails for rack mounting (optional) Cable manager (optional) Protective panel to prevent unauthorized access to the front panel of the server (optional) |
| Power Supply Parameters | 180-264 VAC, 9-3.5 A, 47-63 Hz |
| Operating Environment | Operating temperature from +10°C to +35°C Storage temperature from -40°C to +70°C Relative humidity during storage from 5% to 90% |
| Noise Level | No more than 70 dBA |
| Warranty | Standard warranty 36 months, 9 x 5, service at the service center |
|