| Characteristic |
Description |
 |  |
| Platform | Supermicro AS-2014CS-TR Server Platform |
| Server Board | Super H12SSW-AN6 |
| Server Chassis | CSE-LA26TS-R920AWP |
| Form Factor | 2U, rack mountable Rails included |
| Processor | 1 x AMD EPYC 7002/7003 processor with max TDP 280W Processor socket Socket SP3, AMD Zen 2 (Rome) / Zen 3 (Milan) architecture, 7 nm process technology Up to 64 cores, 128 threads, operating frequency up to 3.7 GHz (maximum 4.1 GHz in Boost mode) Up to 256MB L3 cache per CPU, per core: 512KB L2, 64KB (I)+ 32KB (D) L1 Support for Precision Boost technologies, SMT multi-threading 2 x 128-bit FMAC compute units (4 floating point instructions per cycle) 128 PCIe 4.0 lanes Supports ECC DDR4-3200 memory, up to 4TB, integrated eight-channel memory controller |
| Chipset | System on Chip (SoC) (the chipset is built into the processor) |
| System Memory | Memory types: ECC DDR4 Registered DIMM (RDIMM), ECC DDR4 Load Reduced DIMM (LRDIMM) Memory operating frequency 3200 MT/s Maximum capacity: for RDIMM - 2048GB (16x128GB), for LRDIMM - 4096GB (16x256GB) Eight-channel memory controller, 16 DIMM slots (2 modules per channel) Memory subsystem bandwidth from 85.3 GB/s to 204.8 GB/s depending on the processor model |
| Network Controller | One or two AIOM PCIe 4.0 x16 modules of OCP 3.0 standard (1/2/4 ports 1GbE/10GbE/25GbE/100GbE per module) Dedicated management port RJ45 Dedicated IPMI LAN port |
| Expansion Slots | 4 PCIe 4.0 x16/x16 full-height 10.5" long (FHFL) slots via riser cards Or 6 slots: 2 PCIe 4.0 x16/x16 full-height 10.5" long (FHFL) slots via riser cards 2 x PCIe 4.0 x8/x16 full-height 10.5" long (FHFL) via riser cards 2 x PCIe 4.0 x8/x16 full-height half-length (FHFL) slots via riser cards |
| Disk Subsystem Controller | Integrated SATA controller, 16 ports 6Gb/s, connector SLIMLINE x8 , 2 connectorsSLIMLINE x4 Low Profile, combined with 4 NVMe PCIe 4.0 x4 ports 12 NVMe PCIe 4.0 x4 ports, 3 connectorsSLIMLINE x8 , 6 connectorsSLIMLINE x4 LowProfile on the motherboard (8 of 12 ports are used for expansion cards) 2 x M.2 2280/22110 PCIe 4.0 x4 SSD slots on motherboard Additionally: SAS RAID controllers or SAS/FC HBA adapters from the configurator list in expansion slots |
| Disk Subsystem | Up to 12 hot-swappable 3.5"/2.5" HDD/SSD SAS3/SATA3/NVMe in the basket on the front panel Cable connection sockets on the basket: 3 socketsSLIMLINE x4 for SAS/SATA drives, 6 connectorsSLIMLINE x8 for NVMe drives Installing more than 4 NVMe drives in the front panel cage is possible by using the ports that the expansion slots are connected to. It is also possible to connect additional NVMe drives to 3-Mode controllers. Additional cables are required to install NVMe drives with motherboard or 3-Mode controller connections. Additional cables are required to install SAS drives connected to a RAID controller or HBA. Additionally: 2 x 2.5" SAS/SATA/NVMe drives in rear cage (optional) |
| Additional Storage | Up to 2 M.2 2280/22110 PCIe 4.0 x4 drives in motherboard slots Up to 2 M.2 2260/2280/22110 drives with PCIe 3.0 x4 interface when installing an additional cage in the form of a PCIe 3.0 x8 expansion card Up to 4 M.2 2260/2280/22110 drives with PCIe 3.0 x4 interface when installing an additional cage in the form of a PCIe 3.0 x8 expansion card Up to 2 x M.2 2280/22110 PCIe 3.0 x4 or SATA drives when installed in an expansion card with Boot RAID 0/1 support based on Broadcom SAS3408 |
| Optical Storage | Not supported |
| Interfaces | DB-15 video connector, rear panel up to 8 network ports on the rear panel (depending on the type of AIOM modules selected) 1Gb Ethernet RJ-45 management port, rear panel 2 USB 3.0 ports on the rear panel 2 internal USB 2.0 ports 1 serial port on rear panel |
| Video Adapter | Integrated ASPEED AST2600 BMC Graphics controller |
| Control Panel | Control buttons: Power On/Off, UID Indication: Power Status LED, HDD activity LED, 2 x Network activity LED, UID LED |
| Management and Monitoring | Intelligent Platform Management Interface v.2.0 (IPMI 2.0) Virtual media over LAN, KVM-over-LAN, ASPEED AST2600 Base Management Controller (BMC) Monitoring voltages, temperatures, fan speeds Case opening sensor The server comes with a license for remote BIOS update (SFT-OOB-LIC) |
| Supported Operating Systems | Current list |
| Power Unit | x 920W Platinum Hot-Swap Redundant Power Supplies (AC) |
| System Cooling | 3 x 80mm hot-swappable system fans, 13.5K RPM |
| Dimensions | Height 8.9 cm, width 43.7 cm, depth 64.8 cm |
| Weight | 16.1 kg, in packaging 26.8 kg (platform) |
| Power Supply Parameters | 200 - 240Vac / 4.5 - 3.8A / 50-60Hz |
| Operating Environment | Operating temperature from +10°C to +35°C Storage temperature from -40°C to +60°C Operating relative humidity from 8% to 90% Relative humidity during storage from 5% to 95% |
| Warranty | Standard 36 months warranty, service at the service center |